Calibration and Testing

Reading the VEGA Software Version

To read the VEGA Unit's Software Version, pro-
ceed as follows:
EEPROM version read (V)
1. Select "
a) from the Pull Down Menu from the VEGA
Calibration Program Tool Bar Menu Selection.
Figure 6-85 Tool Bar Menu 8
Figure 6-85 Tool Bar Menu 8
read complete
2. The "
(Figure 6-86) to show current Software Version.
OK
Click on the "
"
to accept the read state reported.

Figure 6-86 Software Version Indication

a
Figure 6-86 Software Version Indication

Calibration without PC

To perform calibration without the PC, proceed as 
follows:
1. Confirm that the interconnection for performing
the VEGA calibration without the PC referring
illustration shown in Figure 6-87.

Figure 6-87 Tool and Harness Connection

Interface Connector
Receptacle
e
d
To AC Power
a) VEGA Unit
b) Power Supply
c) Harness
d) White Reference Paper KS-325
e) Black Reference Paper KS-326
Figure 6-87 Tool and Harness Connection
WARNING: Ensure that the VEGA Unit's
power is OFF before connecting
harnesses. Connecting harnesses
while the power is ON may damage the
VEGA or cause electrical shock.
P/N 960-100189R_Rev. 4 {EDP #148850}
VEGA™ Series Banknote Validator
" (Figure 6-85
a
" Dialog Window appears
Button (Figure 6-86 a)
c
a
b
2. Turn the VEGA Unit's power
3. Set DIP Switch DS1 Switches #1, #2 and #8 to
ON
, and set DIP Switch DS2 Switches ALL
as shown in Figure 6-88.
NOTE: DIP Switch Block 3 settings
are not required to perform this
Calibration Procedure.

Figure 6-88 DIP Switch Settings

DIP Switch Block No.1
DIP Switch Block No.2
Figure 6-88 DIP Switch Settings
4. Turn the VEGA Unit's power
that the Front Panel LED slowly flashes at a
Green
Color rate.
5. Set DIP Switch DS1 Switch #1 to
VEGA into the Adjustment Mode, and confirm
that the Front Panel LED slowly flashes at a
Color rate.
6. Set DIP Switch DS2 Switch #1 to ON to begin the
Entrance Sensor Calibration without Reference
Paper. During the adjustment process, the Front
Panel LED flashes a
speed.
NOTE: Do not touch the VEGA Unit
while performing calibration,
otherwise, the adjustment changes
will not accurately calibrate the Unit.
NOTE: Keep DIP Switch Block 2
Switch #1 ON until instructed to turn
the switch to OFF.
7. Once the Entrance Sensor Calibration without
Reference Paper procedure is complete, the Front
Panel LED slowly flashes at a White Color rate.
Set the White Reference paper in place (See
"Placing Reference Paper" on page 6-5).
8. Set DIP Switch DS2 Switch #2 to
Validation Sensor Calibration with the White Ref-
erence Paper. During the adjustment process, the
Front Panel LED flashes a White Color at a high
rate of speed.
NOTE: Keep DIP Switch Block 2
Switch #1 and #2 ON until instructed
to turn the switches to OFF.
9. Once the Validation Sensor Calibration with
White Reference Paper procedure is complete, the
Front Panel LED slowly flashes at a
rate.
© 2016, JAPAN CASH MACHINE CO., LTD.
6 - 1 5
Section 6
OFF
.
OFF
ON
, and confirm
OFF
to turn the
Cyan
Cyan
Color at a high rate of
ON
to begin the
Blue
Color