D: References - YASKAWA T1000A Technical Manual

Table of Contents

Advertisement

B.3 Parameter Table
u d: References
Reference parameters are used to set the various frequency reference values during operation.
n
d1: Frequency Reference
No.(Addr.)
Name
d1-01
(280H)
Frequency Reference 1
d1-02
(281H)
Frequency Reference 2
d1-03
(282H)
Frequency Reference 3
d1-04
(283H)
Frequency Reference 4
d1-05
(284H)
Frequency Reference 5
d1-06
(285H)
Frequency Reference 6
d1-07
(286H)
Frequency Reference 7
d1-08
(287H)
Frequency Reference 8
d1-17
(292H)
Jog Frequency Reference
<11> Range upper limit is determined by the maximum output frequency (E1-04) and the upper limit of the frequency reference (d2-01).
<40> When using the AOLV/PM or CLV/PM control mode, the drive will automatically set parameter o1-03 = 1 and percentage units will be used.
n
d2: Frequency Upper/Lower Limits
No.(Addr.)
Name
d2-01
Frequency Reference Upper Limit
(289H)
d2-02
(28AH)
Frequency Reference Lower Limit
d2-03
(293H)
Master Speed Reference Lower
Limit
d2-04
(2A8H)
Frequency Reference 2 Upper
Limit
d2-05
(2A9H)
Frequency Reference 2 Lower
Limit
n
d5: Torque Control
No.(Addr.)
Name
d5-01
Torque Control Selection
(29AH)
378
All Modes
Sets the frequency reference for the drive. Setting units are determined by parameter o1-03.
All Modes
Sets the frequency reference for the drive. Setting units are determined by parameter o1-03.
All Modes
Sets the Jog frequency reference. Setting units are determined by parameter o1-03.
All Modes
Sets the frequency reference upper limit as a percentage of the maximum output frequency.
All Modes
Sets the frequency reference lower limit as a percentage of the maximum output frequency.
All Modes
Sets the lower limit for frequency references from analog inputs as a percentage of the
maximum output frequency.
All Modes
Sets the frequency reference 2 upper limit as a percentage of maximum output frequency.
All Modes
Sets the frequency reference 2 lower limit as a percentage of maximum output frequency.
V/f
V/f w/PG
OLV/PM
AOLV/PM
0: Speed Control
1: Torque Control
Set to 0 when using a digital input to switch between Speed and Torque Control (H1-
YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual
Description
Description
Description
OLV
CLV
CLV/PM
Setting
Page
155
155
155
Default: 0.00 Hz
Min: 0.00 Hz
Max: 400.00 Hz
<11> <40>
155
155
155
155
Default: 0.00 Hz
Min: 0.00 Hz
Max: 400.00 Hz
<11> <40>
155
Default: 6.00 Hz
Min: 0.00 Hz
155
Max: 400.00 Hz
<11> <40>
Setting
Page
Default: 100.0%
Min: 0.0%
157
Max: 110.0%
Default: 0.0%
Min: 0.0%
157
Max: 110.0%
Default: 0.0%
Min: 0.0
157
Max: 110.0%
Default: 100.0%
Min: 0.0%
157
Max: 110.0%
Default: 100.0%
Min: 0.0%
157
Max: 110.0%
Setting
Page
Default: 0
Min: 0
160
Max: 1
= 71).

Hide quick links: