2.2 Mechanical Installation
Internal/Flush-Mount
An internal flush-mount requires an installation support set that must be purchased separately. Contact your Yaskawa
representative to order an installation support set and mounting hardware.
Installation Support Set A.
1.
Cut an opening in the enclosure panel for the digital operator as shown in
2.
Mount the digital operator to the installation support.
3.
Mount the installation support set and digital operator to the enclosure panel.
Figure 2.8
M4 × 10
Phillips truss head screw × 4
(for panel widths between 1 and 1.6)
Note: For environments with a significant amount of dust or other airborne debris, use a gasket between the enclosure panel and the
digital operator.
Figure 2.9
40
Figure 2.8 Internal/Flush Mount Installation
Figure 2.9 Panel Cut-Out Dimensions (Internal/Flush-Mount Installation)
Figure 2.8
Enclosure panel
Digital Operator
45
+0.5
59
0
Unit : mm
YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual
illustrates how to attach the
Figure
2.9.
Installation Support Set A
M3 × 6
Phillips recessed
pan head machine screw × 2
Unit: mm