n
b2: DC Injection Braking and Short Circuit Braking
No.(Addr.)
Name
b2-01
(189H)
DC Injection Braking Start
Frequency
b2-02
(18AH)
DC Injection Braking Current
b2-03
(18BH)
DC Injection Braking Time at Start
b2-04
(18CH)
DC Injection Braking Time at Stop
b2-08
Magnetic Flux Compensation
(190H)
Value
b2-10
DC Injection Braking Current 2
(1FBH)
b2-12
Short Circuit Brake Time at Start
(1BAH)
b2-13
Short Circuit Brake Time at Stop
(1BBH)
b2-18
Short Circuit Braking Current
(177H)
<23> A coasting motor may require a braking resistor circuit to bring the motor to a stop in the required time.
<34> Default setting is determined by the control mode (A1-02).
n
b3: Speed Search
No.(Addr.)
Name
b3-01
Speed Search Selection at Start
(191H)
b3-02
(192H)
Speed Search Deactivation Current
b3-03
(193H)
Speed Search Deceleration Time
b3-04
(194H)
V/f Gain during Speed Search
b3-05
(195H)
Speed Search Delay Time
b3-06
(196H)
Output Current 1 during Speed
Search
YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual
All Modes
Sets the frequency to start executing DC Injection Braking, Short-Circuit Braking, and Zero
Servo. Enabled when the stopping method is set for ramp to stop (b1-03 = 0).
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the DC Injection Braking current as a percentage of the drive rated current.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the time of DC Injection Braking (Zero Speed Control when in CLV and CLV/PM) time at
start. Disabled when set to 0.00 seconds.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the time of DC Injection Braking (Zero Speed Control when in CLV and CLV/PM) at stop.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the magnetic flux compensation as a percentage of the no-load current value (E2-03).
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the DC Injection Braking 2 current as a percentage of the drive rated current.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the time for Short Circuit Braking operation at start.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the Short Circuit Braking operation time at stop.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Determines the current level for Short Circuit Braking. Set as a percentage of the motor rated
current.
V/f
V/f w/PG
OLV/PM
AOLV/PM
0: Disabled
1: Enabled
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the current level at which the speed is assumed to be detected and Speed Search is ended.
Set as a percentage of the drive rated current.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets output frequency reduction time during Speed Search.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Determines how much to lower the V/f ratio during Speed Search.
V/f during Speed Search equals the V/f setting multiplied by b3-04.
All Modes
When using an external contactor on the output side, b3-05 delays executing Speed Search after
a momentary power loss to allow time for the contactor to close.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the current injected to the motor at the beginning of Speed Estimation Speed Search. Set as
a coefficient for the motor rated current.
Description
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
<23>
OLV
CLV
CLV/PM
<23>
OLV
CLV
CLV/PM
Description
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
B.3 Parameter Table
Setting
Page
Default:
<34>
Min: 0.0 Hz
118
Max: 10.0 Hz
Default: 50%
Min: 0%
119
Max: 100%
Default: 0.00 s
Min: 0.00 s
119
Max: 10.00 s
Default:
<34>
Min: 0.00 s
120
Max: 10.00 s
Default: 0%
Min: 0%
120
Max: 1000%
Default: 50%
Min: 0%
120
Max: 100%
Default: 0.00 s
Min: 0.00 s
120
Max: 25.50 s
Default: 0.50 s
<34>
Min: 0.00 s
121
Max: 25.50 s
Default: 100.0%
Min: 0.0%
121
Max: 200.0%
Setting
Page
Default:
<34>
Min: 0
124
Max: 1
Default:
<34>
Min: 0%
124
Max: 200%
Default: 2.0 s
Min: 0.1 s
124
Max: 10.0 s
Default:
<24>
Min: 10%
124
Max: 100%
Default: 0.2 s
Min: 0.0 s
124
Max: 100.0 s
Default:
<9>
Min: 0.0
125
Max: 2.0