5.7 H: Terminal Functions
Figure 5.68
Figure 5.68 Frequency Reference Setting by Analog Input with Negative Bias
n
H3-05: Terminal A3 Signal Level Selection
Determines the function assigned to analog input terminal A3.
No.
H3-05
Setting 0: 0 to 10 Vdc
The input level is 0 to 10 Vdc. See the explanation provided for H3-01.
Setting 1: –10 V to 10 Vdc
The input level is -10 to 10 Vdc. See the explanation provided for H3-01.
n
H3-06: Terminal A3 Function Selection
Determines the function assigned to analog input terminal A3.
on page 204
for a list of functions and descriptions.
When analog input A3 is used as PTC input set H3-06 = E and make sure switch S4 on the terminal board is set for PTC
input. Also refer to
Terminal A3 Analog/PTC Input Selection on page
No.
H3-06
n
H3-07, H3-08: Terminal A3 Gain and Bias Setting
Parameter H3-07 sets the level of the selected input value that is equal to 10 Vdc input at terminal A3 (gain).
Parameter H3-08 sets the level of the selected input value that is equal to 0 V input at terminal A3 (bias).
No.
H3-07
H3-08
n
H3-09: Terminal A2 Signal Level Selection
Selects the input signal level for analog input A2. Be sure to also set DIP switch S1 on the terminal board accordingly for
a voltage input or current input.
No.
H3-09
Setting 0: 0 to 10 Vdc
The input level is 0 to 10 Vdc.
Setting 1: –10 to 10 Vdc
The input level is –10 to 10 Vdc.
Setting 2: 4 to 20 mA Current Input
The input level is 4 to 20 mA. Negative input values by negative bias or gain settings will be limited to 0%.
202
H3-01 = 0
100%
Frequency
H3-01 = 0
reference
0
2.0 V
Analog Input
-25%
Voltage
H3-01 = 1
Name
Terminal A3 Signal Level Selection
Name
Terminal A3 Function Selection
Name
Terminal A3 Gain Setting
Terminal A3 Bias Setting
Name
Terminal A2 Signal Level Selection
Refer to Setting 0: 0 to 10 Vdc on page 201
Refer to Setting 1: –10 to 10 Vdc on page
H3-01 = 1
100%
-10 V
-6.0 V
10 V
Refer to Setting 0: 0 to 10 Vdc on page
Refer to Setting 1: –10 to 10 Vdc on page
Refer to Multi-Function Analog Input Terminal Settings
67.
YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual
10 V
2.0 V
Analog Input
-25%
Voltage
-100%
E1-04
-150%
Setting Range
0, 1
Setting Range
0 to 41
Setting Range
-999.9 to 999.9%
-999.9 to 999.9%
Setting Range
0 to 3
201.
Default
0
201.
201.
Default
2
Default
100.0%
0.0%
Default
2

Hide quick links: