YASKAWA T1000A Technical Manual page 381

Table of Contents

Advertisement

No.(Addr.)
Name
E2-05
Motor Line-to-Line Resistance
(312H)
E2-06
Motor Leakage Inductance
(313H)
E2-07
Motor Iron-Core Saturation
(314H)
Coefficient 1
E2-08
Motor Iron-Core Saturation
(315H)
Coefficient 2
E2-09
Motor Mechanical Loss
(316H)
E2-10
Motor Iron Loss for Torque
(317H)
Compensation
E2-11
Motor Rated Power
(318H)
<18> This value's number of decimal places depends on the drive model and the Heavy/Normal duty selection in parameter C6-01. The value will
have two decimal places (0.01A) if the drive is set for a Maximum Applicable Motor Capacity up to 11 kW (refer to
and one decimal place (0.1A) if the set Maximum Applicable Motor Capacity is higher than 11 kW.
<24> Default setting value is dependent on the drive model (o2-04) and the Drive Duty (C6-01).
n
E3: V/f Pattern for Motor 2
These parameters are hidden when a PM motor control mode has been selected for motor 1 (A1-02 = 5, 6, 7).
No.(Addr.)
Name
E3-01
Motor 2 Control Mode Selection
(319H)
YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the phase-to-phase motor resistance. Automatically set during Auto-Tuning.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the voltage drop due to motor leakage inductance as a percentage of motor rated voltage.
Automatically set during Auto-Tuning.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the motor iron saturation coefficient at 50% of magnetic flux. Automatically set during
Auto-Tuning.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the motor iron saturation coefficient at 75% of magnetic flux. Automatically set during
Auto-Tuning.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the motor mechanical loss as a percentage of motor rated power (kW).
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the motor iron loss.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the motor rated power in kilowatts (1 HP = 0.746 kW). Automatically set during
Auto-Tuning.
V/f
V/f w/PG
OLV/PM
AOLV/PM
0: V/f Control
1: V/f Control with PG
2: Open Loop Vector Control
3: Closed Loop Vector Control
Description
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
Description
OLV
CLV
CLV/PM
B.3 Parameter Table
Setting
Page
Default:
<24>
Min: 0.000 Ω
166
Max: 65.000 Ω
Default:
<24>
Min: 0.0%
166
Max: 40.0%
Default: 0.50
Min: 0.00
166
Max: 0.50
Default: 0.75
Min: E2-07
166
Max: 0.75
Default: 0.0%
Min: 0.0%
167
Max: 10.0%
Default:
<24>
Min: 0 W
167
Max: 65535 W
Default:
<24>
Min: 0.00 kW
167
Max: 650.00 kW
Table A.2
and
Table
A.3)
Setting
Page
Default: 0
Min: 0
168
Max: 3
381
B

Hide quick links:

Advertisement

Table of Contents
loading