Register No.
oFC0x Contents (CN5-C)
bit 0
bit 1
bit 2
00E1H
bit 3, 4
bit 5
bit 6
bit 7 to F
oFC1x Contents (CN5-C)
bit 0
bit 1
bit 2
bit 3
00E2H
bit 4
bit 5
bit 6
bit 7
bit 8 to F
00E3H, 00E4H
Reserved
oFC3x Contents (CN5-C)
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
00E5H
bit 7
bit 8
bit 9
bit A
bit B
bit C
bit D
bit E, F
00E6H to 00FAH
Reserved
00FBH
Output Current
00FCH to 00FFH
Reserved
Used for various monitors U9-
0820H to 0824H
Refer to
U9: KEB Voltage Monitors on page 421
<1> Units are determined by parameter o1-03.
<2> This value's number of decimal places depends on the drive model and the Heavy/Normal duty selection in parameter C6-01. The value will
have two decimal places (0.01A) if the drive is set for a Maximum Applicable Motor Capacity up to 11 kW (refer to
and one decimal place (0.1A) if the set Maximum Applicable Motor Capacity is higher than 11 kW.
<3> The contents of a communication error are saved until the fault is reset.
<4> Depending on the motor used, the correct motor pole number must be set to parameter E2-04, E4-04, or E5-05.
u Broadcast Messages
Data can be written from the master to all slave devices at the same time.
The slave address in a broadcast command message must be set to 00H. All slaves will receive the message, but will not
respond.
Register No.
Digital Input Command
bit 0
bit 1
bit 2, 3
bit 4
0001H
bit 5
bit 6 to B
bit C
bit D
bit E
bit F
0002H
Frequency Reference
YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual
Option compatibility error (oFC00)
Option not properly connected (oFC01)
Same type of option card already connected (oFC02)
Reserved
A/D Conversion Fault (oFC05)
Option Response Error (oFC06)
Reserved
Option RAM Fault (oFC10)
Option Operation Mode Fault (SLMOD) (oFC11)
Drive Receive CRC Error (oFC12)
Drive Receive Frame Error (oFC13)
Drive Receive Abort Error (oFC14)
Option Receive CRC Error (oFC15)
Option Receive Frame Error (oFC16)
Option Receive Abort Error (oFC17)
Reserved
Comm. ID Error (oFC30)
Model Code Error (oFC31)
Sumcheck Error (oFC32)
Comm. option timeout waiting for response (oFC33)
MEMOBUS Timeout (oFC34)
Drive timeout waiting for response (oFC35)
CI Check Error (oFC36)
Drive timeout waiting for response (oFC37)
Control Command Selection Error (oFC38)
Drive timeout waiting for response (oFC39)
Control Response Selection 1 Error (oFC40)
Drive timeout waiting for response (oFC41)
Control Response Selection 2 Error (oFC42)
Control Response Selection Error (oFC43)
Reserved
<2>
.
for parameter details.
Forward Run (0: Stop 1: Run)
Direction Command (0: Forward, 1: Reverse)
Reserved
External Fault
Fault Reset
Reserved
Multi-Function Digital Input S5
Multi-Function Digital Input S6
Multi-Function Digital Input S7
Multi-Function Digital Input S8
30000/100%