B.3 Parameter Table
n
H2: Multi-Function Digital Outputs
No.(Addr.)
Name
H2-01
Terminal M1-M2 function
(40BH)
selection (relay)
H2-02
Terminal M3-M4 function
(40CH)
selection (relay)
H2-03
Terminal M5-M6 function
(40DH)
selection (relay)
H2-06
Watt Hour Output Unit Selection
(437H)
H2-
Function
Setting
0
During fun
1
Zero Speed
2
Speed agree 1
3
User-set speed agree 1
4
Frequency detection 1
5
Frequency detection 2
6
Drive ready
7
DC bus undervoltage
8
During baseblock (N.O.)
9
Frequency reference source
A
Run command source
B
Torque detection 1 (N.O.)
C
Frequency reference loss
D
Braking resistor fault
E
Fault
F
Through mode
10
Minor fault
392
All Modes
Refer to
H2 Multi-Function Digital Output Settings on page 392
values.
All Modes
Outputs a 200 ms pulse signal when the watt-hour counter increases by the units selected.
0: 0.1 kWh units
1: 1 kWh units
2: 10 kWh units
3: 100 kWh units
4: 1000 kWh units
H2 Multi-Function Digital Output Settings
All Modes
Closed: A Run command is active or voltage is output.
All Modes
Open: Output frequency is above the minimum output frequency set in E1-09.
Closed: Output frequency is below the minimum output frequency set in E1-09.
All Modes
Closed: Output frequency equals the speed reference (plus or minus the hysteresis set to L4-02).
All Modes
Closed: Output frequency and speed reference equal L4-01 (plus or minus the hysteresis set to L4-02).
All Modes
Closed: Output frequency is less than or equal to the value in L4-01 with hysteresis determined by L4-02.
All Modes
Closed: Output frequency is greater than or equal to the value in L4-01 with hysteresis determined by L4-02.
All Modes
Closed: Power up is complete and the drive is ready to accept a Run command.
All Modes
Closed: DC bus voltage is below the Uv trip level set in L2-05.
All Modes
Closed: Drive has entered the baseblock state (no output voltage).
All Modes
Open: External Reference 1 or 2 supplies the frequency reference (set in b1-01 or b1-15).
Closed: Digital operator supplies the frequency reference.
All Modes
Open: External Reference 1 or 2 supplies the Run command (set in b1-02 or b1-16).
Closed: Digital operator supplies the Run command.
All Modes
Closed: An overtorque or undertorque situation has been detected.
All Modes
Closed: Analog frequency reference has been lost.
All Modes
Closed: Braking resistor or transistor is overheated or faulted out.
All Modes
Closed: Fault occurred.
All Modes
Set this value when using the terminal in the pass-through mode.
All Modes
Closed: An alarm has been triggered, or the IGBTs have reached 90% of their expected life span.
YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual
Description
for a description of setting
Description
Setting
Page
Default: 0
Min: 0
190
Max: 161
Default: 1
Min: 0
190
Max: 161
Default: 2
Min: 0
190
Max: 161
Default: 0
Min: 0
200
Max: 4
Page
191
191
191
192
192
193
193
193
193
194
194
194
194
194
194
194
194