F: Options - YASKAWA T1000A Technical Manual

Table of Contents

Advertisement

<18> This value's number of decimal places depends on the drive model and the Heavy/Normal duty selection in parameter C6-01. The value will
have two decimal places (0.01A) if the drive is set for a Maximum Applicable Motor Capacity up to 11 kW (refer to
and one decimal place (0.1A) if the set Maximum Applicable Motor Capacity is higher than 11 kW.
<24> Default setting value is dependent on the drive model (o2-04) and the Drive Duty (C6-01).
n
E5: PM Motor Settings
No.(Addr.)
Name
E5-01
(329H)
Motor Code Selection
<16>
E5-02
(32AH)
Motor Rated Power
<16>
E5-03
(32BH)
Motor Rated Current
<16>
E5-04
(32CH)
Number of Motor Poles
<16>
E5-05
(32DH)
Motor Stator Resistance
<16>
E5-06
(32EH)
Motor d-Axis Inductance
<16>
E5-07
(32FH)
Motor q-Axis Inductance
<16>
E5-09
Motor Induction Voltage Constant
(331H)
1
<16>
E5-11
Encoder Z-pulse Offset
(333H)
E5-24
Motor Induction Voltage Constant
(353H)
2
<16>
<7> Default setting value is dependent on the motor code set to E5-01.
<16> Parameter setting value is not reset to the default value when the drive is initialized.
<18> This value's number of decimal places depends on the drive model and the Heavy/Normal duty selection in parameter C6-01. The value will
have two decimal places (0.01A) if the drive is set for a Maximum Applicable Motor Capacity up to 11 kW (refer to
and one decimal place (0.1A) if the set Maximum Applicable Motor Capacity is higher than 11 kW.
<19> If using a Yaskawa SMRA Series SPM Motor, the default setting is 1800 r/min.
<24> Default setting value is determined by the drive model (o2-04) and the Drive Duty (C6-01).
<34> Default setting value is determined by the control mode (A1-02).
<37> Selections may vary depending on the motor code entered to E5-01.
u F: Options
F parameters are used to program the drive for PG feedback from the motor and to function with option cards.
n
F1: PG Speed Control Card (PG-B3 / PG-X3)
Parameters F1-01, F1-05, F1-06, F1-12, F1-13, and F1-18 through F1-21 are used to set up a PG option card plugged into
option port CN5-C of the drive. They include "PG 1" in the parameter name.
YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual
V/f
V/f w/PG
OLV/PM
AOLV/PM
Enter the Yaskawa motor code for the PM motor being used. Various motor parameters are
automatically set based on the value of this parameter. Setting that were changed manually will
be overwritten by the defaults of the selected motor code.
Note: Set to FFFF when using a non-Yaskawa PM motor or a special motor.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the rated capacity of the motor.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the motor rated current.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the number of motor poles.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Set the resistance for each motor phase.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the d-axis inductance for the PM motor.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the q-axis inductance for the PM motor.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Set the induced phase peak voltage in units of 0.1 mV (rad/s) [electrical angle]. Set this
parameter when using a Yaskawa SSR1 Series PM motor with derated torque, or a Yaskawa
SST4 Series motor with constant torque.
When setting this parameter, E5-24 should be set to 0.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the offset between the rotor magnetic axis and the Z pulse of an incremental encoder. Set
during Z Pulse Offset Tuning.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Set the induced phase-to-phase rms voltage in units of 0.1 mV/(r/min) [mechanical angle]. Set
this parameter when using a Yaskawa SMRA Series SPM motor.
When setting this parameter, E5-09 should be set to 0.
Description
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
B.3 Parameter Table
Table A.2
and
Table
A.3)
Setting
Page
Default:
<19> <24> <34>
171
Min: 0000
Max: FFFF
<37>
Default:
<7>
Min: 0.10 kW
171
Max: 650.00 kW
Default:
<7>
Min: 10% of drive rated
current
171
Max: 200% of drive
rated current
<18>
Default:
<7>
Min: 2
171
Max: 48
Default:
<7>
Min: 0.000 Ω
171
Max: 65.000 Ω
Default:
<7>
Min: 0.00 mH
172
Max: 300.00 mH
Default:
<7>
Min: 0.00 mH
172
Max: 600.00 mH
Default:
<7>
Min: 0.0 mV/(rad/s)
172
Max:
2000.0 mV/(rad/s)
Default: 0.0 deg
Min: -180 deg
172
Max: 180 deg
Default:
<7>
Min: 0.0 mV/(r/min)
172
Max: 6500.0 mV/(r/
min)
Table A.2
and
Table
A.3)
383
B