B.4 Parameter Defaults Determined by Control Mode (A1-02)
B.4 Parameter Defaults Determined by Control Mode (A1-02)
The tables below list parameters that depend on the control mode selection (A1-02 for motor 1, E3-01 for motor 2).
These parameters are initialized to the shown values if the control mode is changed.
u A1-02 (Motor 1 Control Mode) Dependent Parameters
Table B.2 A1-02 (Motor 1 Control Mode) Dependent Parameters and Default Values
No.
Name
b2-01
DC Injection Braking Start Frequency
b2-04
DC Injection Braking Time at Stop
b2-13
Short Circuit Brake Time at Stop
b3-01
Speed Search Selection at Start
b3-02
Speed Search Deactivation Current
b3-14
Bi-Directional Speed Search Selection
b5-15
PID Sleep Function Start Level
b6-01
Dwell Reference at Start
b6-03
Dwell Reference at Stop
b8-01
Energy Saving Control Selection
b8-02
Energy Saving Gain
b8-03
Energy Saving Control Filter Time Constant
C1-11
Accel/Decel Time Switching Frequency
C2-01
S-Curve Time at Acceleration Start
C3-01
Slip Compensation Gain
C3-02
Slip Compensation Primary Delay Time
C4-01
Torque Compensation Gain
C4-02
Torque Compensation Primary Delay Time
C5-01
ASR Proportional Gain 1
C5-02
ASR Integral Time 1
C5-03
ASR Proportional Gain 2
C5-04
ASR Integral Time 2
C5-06
ASR Primary Delay Time Constant
C5-07
ASR Gain Switching Frequency
C6-02
Carrier Frequency Selection
E1-04
Maximum Output Frequency
E1-05
Maximum Voltage
<4>
E1-06
Base Frequency
E1-07
Middle Output Frequency
E1-08
Middle Output Frequency Voltage
E1-09
Minimum Output Frequency
E1-10
Minimum Output Frequency Voltage
F1-05
PG 1 Rotation Selection
F1-09
Overspeed Detection Delay Time
L1-01
Motor Overload Protection Selection
L4-01
Speed Agreement Detection Level
L4-02
Speed Agreement Detection Width
L4-03
Speed Agreement Detection Level (+/-)
L4-04
Speed Agreement Detection Width (+/-)
L8-38
Carrier Frequency Reduction Selection
L8-40
Carrier Frequency Reduction Off Delay Time
o1-03
Digital Operator Display Selection
o1-04
V/f Pattern Display Unit
S6-04
DC Bus Adjustment Gain
S6-07
Torque Limit Delay Time
<1> This setting value depends on a Maximum Applicable Motor Capacity: 1000 s in models CIMR-T 2A0138 to 2A0415 and CIMR-T 4A0139
to 4A0362.
<2> Default setting is determined by the drive model (o2-04) and duty selection (C6-01).
<3> This setting value depends on a Maximum Applicable Motor Capacity.
<4> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.
422
Setting
Resolution
Range
0.0 to 10.0
0.1 Hz
0.00 to 10.00
0.01 s
0.00 to 25.50
0.01 s
0 to 1
0 to 200
1%
0,1
0.0 to 400.0
0.1
0.0 to 400.0
0.1
0.0 to 400.0
0.1
0 to 1
0.0 to 10.0
0.1
0.00 to 10.00
0.01 s
0.0 to 400.0
0.1
0.00 to 10.00
0.01 s
0.0 to 2.5
0.1
0 to 10000
1 ms
0.00 to 2.50
0.01
0 to 60000
1 ms
0.00 to 300.00
0.01
0.000 to 10.000
0.001 s
0.00 to 300.00
0.01
0.000 to 10.000
0.001 s
0.000 to 0.500
0.001 s
0.0 to 400.0
0.1
1 to F
40.0 to 400.0
0.1 Hz
0.0 to 255.0
0.1 V
0.0 to 400.0
0.1 Hz
0.0 to 400.0
0.1 Hz
0.0 to 255.0
0.1 V
<4>
0.0 to 400.0
0.1 Hz
0.0 to 255.0
0.1 V
<4>
0 to 1
0.0 to 2.0
0.1 s
0 to 6
0.0 to 400.0
0.1
0.0 to 20.0
0.1 Hz
-400.0 to 400.0
0.1
0.0 to 20.0
0.1 Hz
0 to 2
0.00 to 2.00
0.01 s
0 to 3
0, 1
0.00 to 5.00
0.01
0.000 to 1.000
0.001 s
YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual
Control Modes (A1-02)
V/f (0)
V/f w/PG (1)
0.5
0.5
0.50
0.50
0
1
120
1
0
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0
0
0.0 Hz
0.0 Hz
0.20
0.20
0.0
2000
1.00
1.00
200
200
<1>
<1>
0.20
0.200
0.02
0.050
1
1
<2>
<2>
50.0
50.0
200.0
200.0
50.0
50.0
2.5
2.5
15.0 (Motor Capacity:
0.55 to 4.0 kW)
<5>
14.0 (5.5 to 45 kW)
12.0 (55 kW and above)
1.3
1.3
9.0 (Motor Capacity:
0.55 to 4.0 kW)
<6>
7.0 (5.5 to 45 kW)
6.0 (55 kW and above)
0
1.0
1
1
0.0 Hz
0.0 Hz
2.0
2.0
0.0 Hz
0.0 Hz
2.0
2.0
<2>
<2>
0.50
0.50
0
0
1.00
1.00
OLV (2)
CLV (3)
0.5
0.5
0.50
0.50
0
100
1
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0
0
0.7
1.0
0.50
0.01
2.00 (Motor Capacity:
0.05 (Motor Capacity:
55 kW and above)
55 kW and above)
0.0 Hz
0.0 Hz
0.20
0.20
1.0
1.0
200
1.00
20
20.00
0.500
20.00
0.500
0.004
0.0 Hz
1
1
<2>
50.0
50.0
200.0
200.0
50.0
50.0
3.0
14.4 (Motor Capacity:
0.55 to 4.0 kW)
13.2 (5.5 kW and
above)
0.5
0.0
3.0 (Motor Capacity:
0.55 to 4.0 kW)
2.4 (5.5 kW and above)
0
0.0
1
1
0.0 Hz
0.0 Hz
2.0
2.0
0.0 Hz
0.0 Hz
2.0
2.0
<2>
<2>
0.50
0.50
0
0
0
0.30
0.30