Prerequisites
Required role: Storage Administrator (Performance Management)
Procedure
1.
Open the Performance Monitor window.
In Command View Advanced Edition:
1.
On the Resources tab, expand the Storage Systems tree.
2.
Right-click the target storage system, and then select Performance Monitor.
In Remote Web Console:
1.
Select Analytics in Explorer, and select Performance Monitor in the tree to open the
Performance Monitor window.
2.
In the Performance Monitor window click Edit Monitoring Switch to open the Edit
Monitoring Switch window.
3.
Click Enable in the Monitoring Switch field.
4.
Select the sampling interval in the Sample Interval. This option is activated when you specify
Enable for Current Status.
5.
Click Finish.
6.
In the Confirm window enter your task name in Task Name, and click Apply to start
monitoring.
In CVAE you can check the progress of the task on the Tasks & Alerts tab. Click the task
name to view details of the task.
In RWC the Tasks window opens if Go to tasks window for status is checked.
NOTE:
Monitoring data cannot be displayed within the first two sampling intervals after the
monitoring starts or the sampling interval is changed because no monitoring data has accumulated.
For instance, if the sampling interval is set to 15 minutes, monitoring data is not accumulated for
up to 29 minutes after the start of monitoring.
Related topics
"Edit Monitoring Switch window" (page 161)

Monitoring WWNs

This section provides instructions for monitoring WWNs using Performance Monitor:
"Adding new WWNs to monitor" (page 16)
"Viewing the WWNs that are being monitored" (page 16)
"Removing WWNs to monitor" (page 17)
"Adding WWNs to ports" (page 17)
"Editing the WWN nickname" (page 18)
"Connecting WWNs to ports" (page 19)
"Deleting unused WWNs from monitoring targets" (page 19)