Performance Monitor Data Graphs; Export Tool For Performance Monitor; Cautions And Restrictions For Performance Monitor; Cautions And Restrictions For Monitoring - HPE XP7 User Manual

Performance for open and mainframe systems
Hide thumbs Also See for XP7:
Table of Contents

Advertisement

You can collect the following statistics in long-range monitoring:
Usage rates of MPs
Usage rates of DRRs
Write-pending statistics
Access path usage statistics
Data drive usage statistics
Data drive access rates

Performance Monitor data graphs

You can view both the short-range and long-range statistics on data graphs. All statistics can be
viewed in short range (for the storing period corresponding to the sampling interval setting).
Usage statistics about storage system resources, which are monitored in both ranges, can be
viewed in both short range and long range. When viewing usage statistics about resources, you
can specify the range to view and which part of the storing period to display on lists and graphics.
A few storage system usage statistics are not available for long-range monitoring.
For details about the Performance Monitor data graphs, see

Export Tool for Performance Monitor

The Export Tool software that comes with Performance Monitor allows you to export the monitoring
data in a .csv file for analysis, for example, using spreadsheet software or database software.
You can also use Export Tool to save and accumulate data over extended periods of time for
long-term analysis and future reference.
For details about Export Tool, see

Cautions and restrictions for Performance Monitor

"Cautions and restrictions for monitoring" (page 11)
"Cautions and restrictions for usage statistics" (page 12)

Cautions and restrictions for monitoring

Performance monitoring switch
When the performance monitoring switch is set to disabled, short-range monitoring data is
not collected.
Changing the SVP time setting
If the SVP time setting is changed while the monitoring switch is enabled, the following
monitoring errors can occur:
Invalid monitoring data appears.
No monitoring data is collected.
If you have changed the SVP time setting, disable the monitoring switch, and then re-enable
the monitoring switch. Next, obtain the monitoring data. For details about the monitoring
switch, see
WWN monitoring
You must configure some settings before the traffic between host bus adapters and storage
system ports can be monitored. For details, see
"Adding WWNs to ports" (page
"Exporting Performance Monitor data" (page
"Starting monitoring" (page
17), and
"About the data graphs" (page
14).
"Adding new WWNs to monitor" (page
"Connecting WWNs to ports" (page
Cautions and restrictions for Performance Monitor
25).
49).
16),
19).
11

Advertisement

Table of Contents
loading

Table of Contents