6.7 DISPlay Group
:DISPlay:BAR:ORDer
Function
Sets the start and end orders of the bar graph or
queries the current setting.
Syntax
:DISPlay:BAR:ORDer {<NRf>,<NRf>}
:DISPlay:BAR:ORDer?
1st <NRf> = 0 to 90 (start order to be displayed)
2nd <NRf> = 10 to 100 (end order to be
displayed)
Example
:DISPLAY:BAR:ORDER 1,100
:DISPLAY:BAR:ORDER? ->
:DISPLAY:BAR:ORDER 1,100
Description • This command is valid only on models with
the advanced computation function (/G6
option) or the harmonic measurement
function (/G5 option).
• Set the start order and then the end order.
• Set the end order so that it is greater than or
equal to (start order + 10).
:DISPlay:CBCycle?
Function
Queries all settings related to the Cycle by
Cycle display.
Syntax
:DISPlay:CBCycle?
Example
:DISPLAY:CBCYCLE? -> :DISPLAY:
CBCYCLE:ITEM1 FREQ;ITEM2 U,1;
ITEM3 I,1;ITEM4 P,1;ITEM5 S,1;
CURSOR 1
Description Only available with the Cycle by Cycle function
(/CC option).
:DISPlay:CBCycle:CURSor
Function
Sets the cursor position of the Cycle by Cycle
display or queries the current setting.
Syntax
:DISPlay:CBCycle:CURSor {<NRf>}
:DISPlay:CBCycle:CURSor?
<NRf> = 1 to 3000 (cursor position)
Example
:DISPLAY:CBCYCLE:CURSOR 1
:DISPLAY:CBCYCLE:CURSOR? ->
:DISPLAY:CBCYCLE:CURSOR 1
Description • Only available with the Cycle by Cycle
function (/CC option).
• Specifies the cursor position by the cycle
number.
6-30
:DISPlay:CBCycle:ITEM<x>
Function
Sets the displayed items (function and element)
of the Cycle by Cycle display or queries the
current setting.
Syntax
:DISPlay:CBCycle:
ITEM<x> {<Function>,<Element>}
:DISPlay:CBCycle:ITEM<x>?
<x> = 1 to 5 (item number)
<Function> = {FREQ|U|I|P|S|Q|LAMBda|
SPEed|TORQue|PM}
<Element> = {<NRf>|SIGMA|SIGMB} (<NRf>
= 1 to 4)
Example
:DISPLAY:CBCYCLE:ITEM1 U,1
:DISPLAY:CBCYCLE:ITEM1? ->
:DISPLAY:CBCYCLE:ITEM1 U,1
Description • Only available with the Cycle by Cycle
function (/CC option).
• When <Function> = {FREQ|SPEed|
TORQue|PM}, <Element> need not be
specified. <Element> is omitted from the
response.
• When <Element> is omitted, Element 1 is set.
• {SPEed|TORQue|PM} is only available with
the motor version (-MV).
:DISPlay:CBCycle:PAGE
Function
Sets the number of the displayed page of the
Cycle by Cycle display or queries the current
setting.
Syntax
:DISPlay:CBCycle:PAGE {<NRf>}
:DISPlay:CBCycle:PAGE?
<NRf> = 1 to 150 (page number)
Example
:DISPLAY:CBCYCLE:PAGE 1
:DISPLAY:CBCYCLE:PAGE? ->
:DISPLAY:CBCYCLE:PAGE 1
Description • Only available with the Cycle by Cycle
function (/CC option).
• When a page number is set, the cursor
moves to the top of the specified page.
:DISPlay:FFT?
Function
Queries all settings related to the FFT waveform
display.
Syntax
:DISPlay:FFT?
Example
:DISPLAY:FFT? -> :DISPLAY:FFT:
FORMAT SINGLE;POINT 20000;
WINDOW RECTANGLE;SCOPE 0,10000;
VSCALE LOG;SPECTRUM LINE;FFT1:
STATE 1;OBJECT U1;LABEL "FFT1";:
DISPLAY:FFT:FFT2:STATE 1;OBJECT I1;
LABEL "FFT2"
Description This command is valid only on models with the
advanced computation function (/G6 option).
IM 760301-17E