6.1 A List of Commands
Command
[:INPut]:CURRent:RANGe:ELEMent<x>
[:INPut]:CURRent:RANGe:{SIGMA|SIGMB}
[:INPut]:CURRent:SRATio?
[:INPut]:CURRent:SRATio[:ALL]
[:INPut]:CURRent:SRATio:ELEMent<x>
[:INPut]:FILTer?
[:INPut]:FILTer:FREQuency?
[:INPut]:FILTer:FREQuency[:ALL]
[:INPut]:FILTer:FREQuency:ELEMent<x>
[:INPut]:FILTer:LINE?
[:INPut]:FILTer[:LINE][:ALL]
[:INPut]:FILTer[:LINE]:ELEMent<x>
[:INPut]:INDependent
[:INPut]:MODUle?
[:INPut]:NULL
[:INPut]:POVer?
[:INPut]:SCALing?
[:INPut]:SCALing:{VT|CT|SFACtor}?
[:INPut]:SCALing:{VT|CT|SFACtor}[:ALL]
[:INPut]:SCALing:{VT|CT|SFACtor}:ELEMent<x>
[:INPut]:SCALing:STATe?
[:INPut]:SCALing[:STATe][:ALL]
[:INPut]:SCALing[:STATe]:ELEMent<x>
[:INPut]:SYNChronize?
[:INPut]:SYNChronize[:ALL]
[:INPut]:SYNChronize:ELEMent<x>
[:INPut]:SYNChronize:{SIGMA|SIGMB}
[:INPut]:VOLTage?
[:INPut]:VOLTage:AUTO?
[:INPut]:VOLTage:AUTO[:ALL]
[:INPut]:VOLTage:AUTO:ELEMent<x> Turns ON/OFF the voltage auto range of the element or queries the current
[:INPut]:VOLTage:AUTO:{SIGMA|SIGMB}
[:INPut]:VOLTage:MODE?
[:INPut]:VOLTage:MODE[:ALL]
[:INPut]:VOLTage:MODE:ELEMent<x> Sets the voltage mode of the element or queries the current setting.
6-10
Function
Sets the current range of the element or queries the current setting.
Collectively sets the current range of all elements belonging to wiring unit
{ΣA|ΣB}.
Queries the current sensor scaling constants of all elements.
Collectively sets the current sensor scaling constants of all elements.
Sets the current sensor scaling constant of the element or queries the
current setting.
Queries all settings related to the input filter.
Queries the frequency filter ON/OFF setting of all elements.
Collectively turns ON/OFF the frequency filter of all elements.
Turns ON/OFF the frequency filter of the element or queries the current
setting.
Queries the line filter settings of all elements.
Collectively sets the line filters of all elements.
Sets the line filter of the element or queries the current setting.
Turns ON/OFF the independent setting of input elements or queries the
current setting.
Queries the input element type.
Turns ON/OFF the NULL function or queries the current setting.
Queries the peak over information.
Queries all settings related to scaling.
Queries the scaling constant of all elements.
Collectively sets the scaling constants of all elements.
Sets the scaling constant of the element or queries the current setting.
Queries the scaling ON/OFF states of all elements.
Collectively turns ON/OFF the scaling of all elements.
Turns ON/OFF the scaling of the element or queries the current setting.
Queries the synchronization source of all elements.
Collectively sets the synchronization source of all elements.
Sets the synchronization source of the element or queries the current
setting.
Collectively sets the synchronization source of all elements belonging to
wiring unit {ΣA|ΣB}.
Queries all settings related to the voltage measurement.
Queries the voltage auto range setting (ON/OFF) of all elements.
Collectively turns ON/OFF the voltage auto range of all elements.
setting.
Collectively turns ON/OFF the voltage auto range of all elements belonging
to wiring unit {ΣA|ΣB}.
Queries the voltage mode of all elements.
Collectively sets the voltage mode of all elements.
Page
6-68
6-68
6-69
6-69
6-69
6-69
6-69
6-69
6-69
6-69
6-69
6-69
6-69
6-70
6-70
6-70
6-70
6-70
6-70
6-70
6-70
6-70
6-71
6-71
6-71
6-71
6-71
6-71
6-71
6-71
6-71
6-71
6-72
6-72
6-72
IM 760301-17E

Advertisement

Table of Contents
loading

Table of Contents