Command
:FILE:SAVE:NUMeric:TYPE
:FILE:SAVE:SETup[:EXECute]
:FILE:SAVE:WAVE?
:FILE:SAVE:WAVE[:EXECute]
:FILE:SAVE:WAVE:TRACe
:FILE:SAVE:WAVE:TYPE
FLICker Group
:FLICker?
:FLICker:COUNt
:FLICker:DC?
:FLICker:DC:LIMit
:FLICker:DC[:STATe]
:FLICker:DISPlay?
:FLICker:DISPlay:ELEMent
:FLICker:DISPlay:PAGE
:FLICker:DISPlay:PERiod
:FLICker:DMAX?
:FLICker:DMAX:LIMit
:FLICker:DMAX[:STATe]
:FLICker:DMIN?
:FLICker:DMIN:LIMit
:FLICker:DT?
:FLICker:DT:LIMit
:FLICker:DT[:STATe]
:FLICker:ELEMent<x>
:FLICker:FREQuency
:FLICker:INITialize
:FLICker:INTerval
:FLICker:JUDGe
:FLICker:MEASurement
:FLICker:MOVe
:FLICker:PLT?
:FLICker:PLT:LIMit
:FLICker:PLT:NVALue
:FLICker:PLT[:STATe]
:FLICker:PST?
:FLICker:PST:LIMit
IM 760301-17E
Function
Sets the format of the numeric data to be saved or queries the
current setting.
Executes the saving of the setup parameter file.
Queries all settings related to the saving of waveform display data files.
Saves the waveform display data to a file.
Sets the waveform to be saved to a file or queries the current setting.
Sets the format of the waveform display data to be saved or queries the
current setting.
Queries all settings related to flicker measurement.
Sets the number of measurements for the short-term flicker value Pst or
queries the current setting.
Queries all settings related to the relative steady-state voltage change dc.
Sets the limit of the relative steady-state voltage change dc or queries the
current setting.
Turns ON/OFF judgment of the relative steady-state voltage change dc or
queries the current setting.
Queries all settings related to flicker measurement display.
Sets the element to be displayed for flicker measurement display or queries
the current setting.
Sets the number of the page to be displayed for flicker measurement display
or queries the current setting.
Sets the observation period number to be displayed for flicker measurement
display or queries the current setting.
Queries all settings related to the maximum relative voltage change dmax.
Sets the limit of the maximum relative voltage change dmax or queries the
current setting.
Turns ON/OFF judgment of the maximum relative voltage change dmax or
queries the current setting.
Queries all settings related to the steady-state range dmin.
Sets the limit of steady-state range dmin or queries the current setting.
Queries all settings related to the relative voltage change time d(t).
Sets the limit of the relative voltage change time d(t) or queries the current
setting.
Turns ON/OFF judgment of the relative voltage change time d(t) or queries
the current setting.
Sets the target element of flicker measurement or queries the current setting. 6-54
Sets the target frequency of flicker measurement or queries the current
setting.
Initializes flicker measurement.
Sets the time per measurement for the short-term flicker value Pst or queries
the current setting.
Stops measurement of dmax caused by manual switching and executes
judgment.
Sets the flicker measurement method or queries the current setting.
Moves the observation period number for measurement of dmax caused by
manual switching.
Queries all settings related to the long-term flicker value Plt.
Sets the limit of the long-term flicker value Plt or queries the current setting.
Sets constant N for the equation used to compute the long-term flicker value
Plt or queries the current setting.
Turns ON/OFF judgment of the long-term flicker value Plt or queries the
current setting.
Queries all settings related to the short-term flicker value Pst.
Sets the limit for the short-term flicker value Pst or queries the current setting. 6-55
6.1 A List of Commands
Page
6-50
6-50
6-50
6-51
6-51
6-51
6-52
6-52
6-52
6-52
6-52
6-52
6-52
6-53
6-53
6-53
6-53
6-53
6-53
6-53
6-53
6-53
6-53
6-54
6-54
6-54
6-54
6-54
6-54
6-54
6-55
6-55
6-55
6-55
6-7
1
2
3
4
5
6
7
App
Index

Advertisement

Table of Contents
loading

Table of Contents