YOKOGAWA WT3000 User Manual page 132

Precision power analyzer communication interface
Hide thumbs Also See for WT3000:
Table of Contents

Advertisement

• The contents of the selections for <Period>
are as follows.
If <Period> is omitted, ALL is set.
ALL
Overall observation period (Result
row of the numeric list in the flicker
measurement display screen)
<NRf> = 1 to 99 specified observation periods
• <Period> is omitted from the response to
output items in the table above for which
specification of <Period> is not required.
:NUMeric:FLICker:INFOrmation:NUMber
Function
Sets the number of flicker judgment results
output by
":NUMeric:FLICker:INFOrmation:VALue?"
or queries the current setting.
Syntax
:NUMeric:FLICker:INFOrmation:
NUMber {<NRf>|ALL}
:NUMeric:FLICker:INFOrmation:
NUMber?
<NRf> = 1 to 32(ALL)
Example
:NUMERIC:FLICKER:INFORMATION:
NUMBER 7
:NUMERIC:FLICKER:INFORMATION:
NUMBER -> :NUMERIC:FLICKER:
FUNCTION:NUMBER 7
Description • Only available with the flicker measurement
function (/FL option).
• If parameters are omitted from
":NUMeric:FLICker:INFOrmation:VALue?",
judgment results from 1 to (specified value)
are output in order.
• The initial setting for the number of judgment
results is 7.
IM 760301-17E
:NUMeric:FLICker:INFOrmation:VALue?
Function
Queries the judgment results (variable format).
Syntax
:NUMeric:FLICker:INFOrmation:
VALue? {<NRf>}
:NUMeric:FLICker:INFOrmation:VALue?
<NRf> = 1 to 32 (item number)
Example
• Example when <NRf> is specified
:NUMERIC:FLICKER:INFORMATION:
VALUE? 1 -> 0
• Example when <NRf> is omitted
:NUMERIC:FLICKER:INFORMATION:
VALUE? -> 0,0,0,0,0,0,0
• Example in which ":NUMeric:FORMat" is set
to "FLOat".
:NUMERIC:FLICKER:INFORMATION:
VALUE? -> #4 (number of bytes, four digits)
(data byte sequence)
Description • Only available with the flicker measurement
function (/FL option).
• When <NRf> is specified, only the judgment
results for that item is output.
• If <NRf> is omitted, judgment results from the
item number in
":NUMeric:FLICker:INFOrmation:NUMber"
is output in order.
• The format of individual judgment results that
are output is as follows:
• Judgment result (JTOTal, JDC, JDMAX,
JDT, JPST, JPLT)
ASCII
FLOAT
(<NR1> format)
(IEEE single-precision floating point
(4-byte) format)
Pass:
"0"
0x00000000 (0)
Fail:
"-1"
0xBF800000 (-1)
Error:
"-2"
0xC0000000 (-2)
-----:
"1"
0x3F800000 (1)
(space):
"1"
0x3F800000 (1)
• No items (NONE)
ASCII: "NAN" (Not A Number)
FLOAT: 0x7E951BEE (9.91E+37)
6.18 NUMeric Group
App
Index
6-89
1
2
3
4
5
6
7

Advertisement

Table of Contents
loading