YOKOGAWA WT3000 User Manual page 59

Precision power analyzer communication interface
Hide thumbs Also See for WT3000:
Table of Contents

Advertisement

6.1 A List of Commands
Command
:SYSTem:LCD:COLor:TEXT?
:SYSTem:LCD:COLor:TEXT:{LETTer|BACKground|BOX|SUB|SELected}
:SYSTem:LCD:COLor:TEXT:MODE
:SYSTem:SLOCk
:SYSTem:TIME
:SYSTem:USBKeyboard
WAVeform Group
:WAVeform?
:WAVeform:BYTeorder
:WAVeform:END
:WAVeform:FORMat
:WAVeform:HOLD
:WAVeform:LENGth?
:WAVeform:SEND?
:WAVeform:SRATe?
:WAVeform:STARt
:WAVeform:TRACe
:WAVeform:TRIGger?
Common Command Group
*CAL?
*CLS
*ESE
*ESR?
*IDN?
*OPC
*OPC?
*OPT?
*PSC
*RST
*SRE
*STB?
*TRG
*TST?
*WAI
6-16
Function
Queries all settings related to the display colors of the text items.
Sets the display color of the {text (Menu Fore)|menu background
(Menu Back)|selected menu (Select Box)|pop-up menu (Sub Menu)|
selected key (Selected Key)} or queries the current setting.
Sets the display color mode of the text items or queries the current setting.
Sets whether to continue the SHIFT key ON state or queries the
current setting.
Sets the time or queries the current setting.
Sets the USB keyboard type or queries the current setting.
Queries all settings related to the waveform display data output.
Sets the output byte order of the waveform display data (FLOAT format)
that is transmitted by ":WAVeform:SEND?" or queries the current setting.
Sets the output end point of the waveform display data that is transmitted
by ":WAVeform:SEND?" or queries the current setting.
Sets the format of the waveform display data that is transmitted by
":WAVeform:SEND?" or queries the current setting.
Sets whether to hold (ON) or release (OFF) all the waveform display data
or queries the current setting.
Queries the total number of points of the waveform specified by
":WAVeform:TRACe".
Queries the waveform display data specified by ":WAVeform:TRACe".
Queries the sample rate of the retrieved waveform.
Sets the output start point of the waveform display data that is transmitted
by ":WAVeform:SEND?" or queries the current setting.
Sets the target waveform for the commands in the WAVeform group or
queries the current setting.
Queries the trigger position of the retrieved waveform.
Executes zero calibration (zero-level compensation, same operation as
pressing CAL (SHIFT+SINGLE)) and queries the result.
Clears the standard event register, extended event register, and error queue. 6-114
Sets the standard event enable register or queries the current setting.
Queries the standard event register.
Queries the instrument model.
Sets a 1 to bit 0 (OPC bit) of the standard event register bit upon the
completion of the specified overlap command.
ASCII code "1" is returned when the specified overlap command is
completed.
Queries the installed options.
Sets whether to clear the registers at power on or queries the current setting. 6-115
Executes the initialization of settings.
Sets the service request enable register or queries the current setting.
Queries the status byte register.
Executes single measurement (the same operation as when SINGLE is
pressed).
Performs a self-test and queries the result.
Holds the subsequent command until the completion of the specified
overlap operation.
Page
6-111
6-111
6-111
6-111
6-111
6-111
6-112
6-112
6-112
6-112
6-112
6-112
6-113
6-113
6-113
6-113
6-113
6-114
6-114
6-114
6-114
6-115
6-115
6-115
6-115
6-115
6-116
6-116
6-116
6-116
IM 760301-17E