YOKOGAWA WT3000 User Manual page 65

Precision power analyzer communication interface
Hide thumbs Also See for WT3000:
Table of Contents

Advertisement

6.4 CBCycle Group
:CBCycle:FILTer?
Function
Queries all settings related to the filter for Cycle
by Cycle measurement.
Syntax
:CBCycle:FILTer?
Example
:CBCYCLE:FILTER? ->
:CBCYCLE:FILTER:LINE:
ELEMENT1 50.0E+03;
ELEMENT2 50.0E+03;
ELEMENT3 50.0E+03;ELEMENT4 50.0E+03
:CBCycle:FILTer:LINE?
Function
Queries all settings related to the line filter for
Cycle by Cycle measurement.
Syntax
:CBCycle:FILTer:LINE?
Example
:CBCYCLE:FILTER:LINE? ->
:CBCYCLE:FILTER:LINE:
ELEMENT1 50.0E+03;
ELEMENT2 50.0E+03;
ELEMENT3 50.0E+03;ELEMENT4 50.0E+03
:CBCycle:FILTer[:LINE][:ALL]
Function
Collectively sets the line filters of all elements
for Cycle by Cycle measurement
Syntax
:CBCycle:FILTer[:LINE][:ALL] {OFF|
<frequency>}
OFF = Line filter OFF
<frequency> = 500 Hz, 5.5 kHz, 50 kHz (line
filter ON, cutoff frequency)
Example
:CBCYCLE:FILTER:LINE:ALL 50KHZ
Description Does not set line filters for motor input.
:CBCycle:FILTer[:LINE]:ELEMent<x>
Function
Sets the line filter of individual elements for
Cycle by Cycle measurement or queries the
current setting
Syntax
:CBCycle:FILTer[:LINE]:
ELEMent<x> {OFF|<frequency>}
:CBCycle:FILTer[:LINE]:ELEMent<x>?
<x> = 1 to 4 (element)
OFF = Line filter OFF
<frequency> = 500 Hz, 5.5 kHz, 50 kHz (line
filter ON, cutoff frequency)
Example
:CBCYCLE:FILTER:LINE:ELEMENT1 50KHZ
:CBCYCLE:FILTER:LINE:ELEMENT1? ->
:CBCYCLE:FILTER:LINE:
ELEMENT1 50.0E+03
6-22
:CBCycle:FILTer[:LINE]:MOTor
Function
Sets the motor input line filters for Cycle by
Cycle measurement or queries the current
setting
Syntax
:CBCycle:FILTer[:LINE]:MOTor {OFF|
<frequency>}
:CBCycle:FILTer[:LINE]:MOTor?
OFF = Line filter OFF
<frequency> = 100 Hz, 50 kHz (line filter ON,
cutoff frequency)
Description Available only with the motor version (-MV).
:CBCycle:RESet
Function
Resets Cycle by Cycle measurement.
Syntax
:CBCycle:RESet
Example
:CBCYCLE:RESET
:CBCycle:STARt
Function
Starts Cycle by Cycle measurement.
Syntax
:CBCycle:STARt
Example
:CBCYCLE:START
:CBCycle:STATe?
Function
Queries the Cycle by Cycle measurement
status.
Syntax
:CBCycle:STATe?
Example
:CBCYCLE:STATE? -> RESET
Description The contents of the response are as follows:
RESet = Reset status
STARt = Measuring
COMPlete = Measurement finished and
measured results displayed
TIMEout = Timeout
ERRFreq = Measurement finished (frequency
measurement error occurred)
:CBCycle:SYNChronize?
Function
Queries all settings related to the
synchronization source for Cycle by Cycle
measurement.
Syntax
:CBCycle:SYNChronize?
Example
:CBCYCLE:SYNCHRONIZE? ->
:CBCYCLE:SYNCHRONIZE:SOURCE U1;
SLOPE RISE
:CBCycle:SYNChronize:SLOPe
Function
Sets the slope of the synchronization source of
Cycle by Cycle measurement or queries the
current setting.
Syntax
:CBCycle:SYNChronize:SLOPe {RISE|
FALL}
:CBCycle:SYNChronize:SLOPe?
Example
:CBCYCLE:SYNCHRONIZE:SLOPE RISE
:CBCYCLE:SYNCHRONIZE:SLOPE? ->
:CBCYCLE:SYNCHRONIZE:SLOPE RISE
IM 760301-17E

Advertisement

Table of Contents
loading