Design and method of operation of the S5-95U with DP master interface
4.2

Pin assignment of the DP master interface

Purpose of the
The DP master interface enables you to connect distributed I/Os to the
interface
S5-95U via the SINEC L2 DP bus.
Assignment
The DP master interface is a 9-way D-Sub port in compliance with the
PROFIBUS-DP draft standard.
Table 4-3 Pin assignment of the DP master interface on the S5-95U
View
Parallel operation
Parallel operation of the DP master interface and PG interface (e.g. SINEC
L1 on PG interface) is possible.
ET 200 Distributed I/O System
EWA 4NEB 780 6000-02a
Pin No.
Signal
1
2
5
3
RxD/TxD-P
9
4
RTS
4
8
8
5
M5V2
3
7
2
2
6
P5V2
6
1
7
8
RxD/TxD-N
9
Designation
Function ground
Data line B
Request to send
Data reference potential (from
station)
Supply plus (from station)
Data line A
Internal assignment
4
4-5