Siemens SIMATIC S5 Manual page 117

Distributed i/o system
Hide thumbs Also See for SIMATIC S5:
Table of Contents

Advertisement

Starting COM ET 200 Windows
ID
Order number
1
8DI
6ES5 420-8MA..
1
2
2
3
3
4
5
5
6
6
7
7
8
8
9
10
7
11
8
12
13
14
Figure 7-10 Example of the "Configure ET 200U" dialog box
7-12
3. Select the ET 200U with order number 6ES5 318-8MB12 as the station
type and click on the "Configure ..." button to switch to the "Configure"
dialog box.
Result: The "Configure ET 200U" dialog box is opened.
Configure: ET 200U
Comment
4. Click on "Order No. ..." to enter the I/O modules of the ET 200U.
Result: A pick list of all I/O modules with order numbers appears.
5. Select, for example, a digital input module 8DI with order number
6ES5 420-8MA.. and press the "OK" button to confirm.
Result: The digital input module is entered in the "Configure ET 200U"
mask.
6. Click the empty field under "I addr." and then press the "Auto addr."
button.
Result: The start of the address area for the digital input module is
automatically defined.
You can overwrite the value in "I addr." with any address of your choice.
7. Press "OK" three times to confirm. COM ET 200 Windows automatically
adds a blank entry.
8. In the "Slaves" window, select station selection by pressing the button.
All the important parameters for the ET 200 distributed I/O system have now
been entered.
I addr.
O addr.
P000
ET 200 Distributed I/O System
OK
Cancel
Order No. ...
ID ...
Comment ...
Reserve
Auto addr.
Delete ...
Help ...
EWA 4NEB 780 6000-02a