Default Setting Changes

To change a default parameter setting, go to the root of the Program menu and turn the Rotary Encoder
until the desired parameter group is within the cursor block and press the Rotary Encoder (repeat if there
is a submenu).
Press the Rotary Encoder to select the default setting to be changed and the selection takes on the reverse
video format (dark background, light text). Turn the Rotary Encoder to change the value of the
parameter. Press the ESC key before accepting the change to exit the menu without saving the change or
press the Rotary Encoder to accept the new setting.
For a complete listing of the Program mode menu options, see the section titled
Program Mode on pg.
34.
Menu items are listed and mapped for convenience. The Direct Access Numbers are listed where
applicable.
The default settings may also be changed by entering the Parameter Number of the setting to be changed
at the Direct Access menu (Program
Direct Access
Applicable Parameter Number). A listing of the
Direct Access Numbers and a description of the associated parameter may be found in the section titled
Direct Access Parameter Information on pg.
48.
A listing of all parameters that have been changed from the default setting may be viewed sequentially by
accessing the Changed From Default screen (Program
Changed From Default).
Note:
Parameter F201 was changed to create the example shown in
Figure 20.
The Changed From Default feature allows the user to view (or change) the parameters that are different
from the default or the post-reset settings. Once the Changed From Default screen is displayed, the
system automatically scrolls through all of the system parameters and halts once reaching a changed
parameter.
The Rotary Encoder may be clicked once clockwise to continue scrolling forward or clicked once
counterclockwise to begin scrolling in reverse. With each click of the Rotary Encoder from a stop, the
system scrolls through all of the parameters and stops at the next parameter that has been changed.
Pressing the Rotary Encoder while a changed parameter is displayed accesses the settings of the changed
parameter for viewing or changing.
Pressing ESC while the system is performing a Changed From Default search terminates the search.
Pressing ESC when done searching (or halted at a changed parameter) returns the system to the Program
Menu.
Figure 20. Changed From Default screen.