F813
Communications Reference Setpoint #2 (%)
Program
Communication Setting Parameters
⇒
Reference Adjust
This parameter is used to set the gain and bias of the Communications
Reference speed control input.
See
F811
for further information on this setting.
This parameter sets the Communications Reference input value that represents
Communications Reference Speed Setpoint #2 (frequency). This value is
entered as 0 to 100% of the Communications Reference input value range.
Communications Speed Setpoint #2 (frequency)
Program
⇒
Communication Setting Parameters
Reference Adjust
This parameter is used to set the gain and bias of the Communications
Reference speed control input.
See
F811
for further information on this setting.
This parameter sets the Communications Reference Speed Setpoint #2.
RS485 Baud Rate
Program
⇒
Communication Setting Parameters
Settings
This parameter sets the RS485 baud rate.
Settings:
1200
2400
4800
9600
19200
38400
RS485 Wire Count
Program
⇒
Communication Setting Parameters
Settings
This parameter sets the communications protocol to the 2 or 4 wire method.
Settings:
2 wire
4 wire
H7 ASD Operation Manual
Direct Access Number — F813
Communication
⇒
Parameter Type — Numerical
Factory Default — 100.0
Changeable During Run — Yes
Minimum — 0.00
Maximum — 100.0
Units — %
Direct Access Number — F814
⇒
Communication
Parameter Type — Numerical
Factory Default — 80.0
Changeable During Run — Yes
Minimum — 0.0
Maximum — Max. Freq. (F011)
Units — Hz
Direct Access Number — F820
⇒
Communication
Parameter Type — Selection List
Factory Default — 9600
Changeable During Run — Yes
Direct Access Number — F821
⇒
Communication
Parameter Type — Selection List
Factory Default — 4
Changeable During Run — Yes
F821