F202
VI/II Speed Reference Setpoint #1 (frequency)
Program
Frequency Setting Parameters
⇒
Setpoints
⇒
VI/II
This parameter is used to set the gain and bias of the VI/II input terminals when
either terminal is used as the control input while operating in the Speed
Control mode.
See
F201
for further information on this setting.
This parameter sets VI/II Speed Reference Setpoint #1 (frequency) and is the
frequency that is associated with the setting of F201.
VI/II Speed Reference Setpoint #2 (%)
Program
⇒
Frequency Setting Parameters
Setpoints
⇒
VI/II
This parameter is used to set the gain and bias of the VI/II input terminals when
either terminal is used as the control input while operating in the Speed
Control or the Torque Control mode.
See
F201
for further information on this setting.
This parameter sets the VI/II input level that represents Reference Setpoint #2
(torque or frequency). This value is entered as 0 – 100% of the VI/II input
signal range.
VI/II Speed Reference Setpoint #2 (frequency)
Program
Frequency Setting Parameters
⇒
Setpoints
⇒
VI/II
This parameter is used to set the gain and bias of the VI/II input terminals when
either terminal is used as the control input while operating in the Speed
Control mode.
See
F201
for further information on this setting.
This parameter sets VI/II Speed Reference Setpoint #2 (frequency) and is the
frequency that is associated with the setting of F203.
VI/II Torque Reference Setpoint #1 (%)
Program
⇒
Torque Setting Parameters
This parameter is used to set the gain and bias of the VI/II input terminals when
either terminal is used as the control input while operating in the Torque
Control mode.
This is accomplished by establishing an associated V/f output pattern for a
given VI/II input level and motor load.
See
F201
for further information on this setting.
This parameter sets Torque Reference Setpoint #1 (%) and is the output
torque value that is associated with the setting of F201. This value is entered as
0 to 250% of the rated torque.
H7 ASD Operation Manual
Speed Reference
⇒
⇒
Speed Reference
Speed Reference
⇒
⇒
Setpoints
⇒
VI/II
Direct Access Number — F202
Parameter Type — Numerical
Factory Default — 0.0
Changeable During Run — Yes
Minimum — 0.0
Maximum — Max. Freq. (F011)
Units — Hz
Direct Access Number — F203
Parameter Type — Numerical
Factory Default — 100.0
Changeable During Run — Yes
Minimum — 0.0
Maximum — 100.0
Units — %
Direct Access Number — F204
Parameter Type — Numerical
Factory Default — 80.0
Changeable During Run — Yes
Minimum — 0.0
Maximum — Max. Freq. (F011)
Units — Hz
Direct Access Number — F205
Parameter Type — Numerical
Factory Default — 0.0
Changeable During Run — Yes
Minimum — 0.0
Maximum — 250.0
Units — %