F368
PG Input Phases
Program
Feedback Parameters
⇒
This parameter determines the type of information that is supplied by the phase
encoder.
Settings:
1 — Speed
2 — Speed and Direction
PG Disconnect Detection
Program
⇒
Feedback Parameters
This parameter Enables/Disables the system's monitoring of the PG connection
status when using encoders with line driver outputs.
Electronic Gear Setting
Program
⇒
Feedback Parameters
This parameter sets the number of pulses per revolution when using a shaft-
mounted encoder and the PG Option Board for closed loop speed control.
Position Loop Gain
Program
⇒
Feedback Parameters
This parameter provides a divisor for the pulse input when operating in the
Pulse Control mode.
118
PG Settings
⇒
⇒
PG Settings
⇒
PG Settings
⇒
PG Settings
Direct Access Number — F368
Parameter Type — Selection List
Factory Default — 2
Changeable During Run — No
Minimum — 1
Maximum — 2
Units — Phase Count
Direct Access Number — F369
Parameter Type — Selection List
Factory Default — Disabled
Changeable During Run — No
Direct Access Number — F370
Parameter Type — Numerical
Factory Default — 1000
Changeable During Run — No
Minimum — 100
Maximum — 4000
Direct Access Number — F371
Parameter Type — Numerical
Factory Default — 4.00
Changeable During Run — Yes
Minimum — 0.0
Maximum — 100.0
H7 ASD Operation Manual