Link Reactor Information; Appendix F - Toshiba H7 Operation Manuals

Adjustable speed drive
Hide thumbs Also See for H7:
Table of Contents

Advertisement

Appendix F

Link Reactor Information

Selection of a link reactor (DCL) is often application specific. This document will provide guidelines for
selecting link reactors for the H7 series of drives.
The 600 Volt series drives above 15 HP allow for the reactor to be mounted internal to the drive. All other
H7 drives require that the DCL be mounted externally.
When selecting and mounting an external DCL, the air flow around the reactor, the thermal capability of
the reactor, the allowable voltage loss, and the amount of harmonic reduction required will be
considerations.
Model Number
VT130H7U
2080
2110
2160
2220
2270
4110
4160
4220
4270
4330
4400
4500
4600
4750A
410KA
6060
6120
6160
6220
6270
6330
6400
6500
6600
208
Table 17 . DCL Selection Table.
DCL Part
DCL Inductance
Number
(mH)
36350
0.40
36351
0.30
36376
0.20
36353
0.20
36355
0.10
36358
1.30
36359
0.90
36360
0.70
36361
0.50
36363
0.40
36364
0.30
36365
0.20
36365
0.20
36366
0.20
42769
0.14
36356
2.50
36359
0.90
36359
0.90
36360
0.70
36362
0.50
36361
0.50
36363
0.40
36363
0.40
36364
0.30
Appendix F
DCL
(Amps)
30.0
38.0
57.0
76.0
114
20.0
29.0
39.0
50.0
75.0
88.0
114
114
141
205
11.0
29.0
29.0
39.0
55.0
50.0
75.0
75.0
88.0
H7 ASD Operation Manual