807" Crrnkecvkqp"Gzcorng"hqt"OCE"XNCP"
Pgvyqtm"Tgswktgogpvu"
Switch A and switch B are connected to meeting room A and meeting room B respectively, and
the two rooms are for all departments;
Notebook A and Notebook B, special for meeting room, are of two different departments;
The two departments are in VLAN10 and VLAN20 respectively. The two notebooks can just
access the server of their own departments, that is, Server A and Server B, in the two meeting
rooms;
The MAC address of Notebook A is 00-19-56-8A-4C-71, Notebook B's MAC address is
00-19-56-82-3B-70.
Pgvyqtm"Fkcitco"
Eqphkiwtcvkqp"Rtqegfwtg"
Configure switch A
Uvgr" Qrgtcvkqp"
1
Configure
Link Type of the
ports
2
Create VLAN10
3
Create VLAN20
Fguetkrvkqp"
the
Required. On XNCP→:2403S"XNCP→Rqtv"Eqphki"page, configure the
link type of Port 11 and Port 12 as GENERAL and TRUNK respectively.
Required. On XNCP→:2403S" XNCP→XNCP" Eqphki" page, create a
VLAN with its VLAN ID as 10, owning Port 11 and Port 12, and
configure the egress rule of Port 11 as Untag.
Required. On XNCP→:2403S" XNCP→XNCP" Eqphki" page, create a
VLAN with its VLAN ID as 20, owning Port 11 and Port 12, and
configure the egress rule of Port 11 as Untag.