Note:
To configure the User Info table, make sure that you have enabled the feature, as
described in Enabling the User Info Table on page804.
If a User Info file is loaded to the device (as described in ''Configuring GW User
Info Table in Loadable Text File'' on page 808), all previously configured entries
are removed from the table in the Web interface and replaced with the entries from
the loaded User Info file.
To configure the GW User Info table through the Web interface:
1.
Open the GW User Info table (Setup menu > Signaling & Media tab > Gateway
folder > User Information).
2.
Click New; the following dialog box appears:
3.
Configure a user according to the table below.
4.
Click Apply.
5.
To register a user, select the user's table entry, and then from the Action drop-down
list , choose Register. To un-register a user, select the user, and then from the Action
drop-down list , choose Un-Register.
Table 44-2: GW User Info Table Parameter Descriptions
Parameter
Index
[GWUserInfoTable_Index]
PBX Extension
[GWUserInfoTable_PBXExtension]
Global Phone Number
[GWUserInfoTable_GlobalPhoneNumber]
User's Manual
Figure 44-6: GW User Info Table - Add Dialog Box
Defines an index number for the new table row.
Note: Each row must be configured with a unique index.
Defines the PBX extension number.
The valid value is a string of up to 10 characters.
Note: The parameter is mandatory.
Defines the "global" phone number for the IP side.
The valid value is a string of up to 20 characters.
Note: The parameter is mandatory.