Fxo Line Testing - AudioCodes Mediant 1000B User Manual

Gateway & enterprise sbc
Hide thumbs Also See for Mediant 1000B:
Table of Contents

Advertisement

62.2

FXO Line Testing

The device can test the telephone lines connected to its FXO ports through SNMP using
the SNMP acAnalogFxoLineTestTable table. The tests provide various line measurements.
In addition to the tests, a keep-alive test is also done every 100 msec on each of the
analog ports to detect communication problems with the analog equipment:
Line Current (mA)
Line Voltage (V)
Hook (0 = on-hook; 1 = off-hook)
Ring (0 - Off; 1 - On)
Line Connected (0 = Disconnected; 1 = Connected)
Polarity state (0 = Normal; 1 = Reversed, 2 = N\A)
Line polarity (0 = Positive; 1 = Negative)
Message Waiting Indication (0 = Off; 1 = On)
You can also view the above information through the Web interface (see ''Viewing Port
Information'' on page 871).
Note:
Analog line testing is traffic affecting and therefore, do the test only for
monitoring and when there are no active calls in progress.
User's Manual
Mediant 1000B Gateway & E-SBC
980
Document #: LTRT-27055

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents