65.1.6 Serial Parameters

The serial interface parameters are described in the table below.
Parameter
[DisableRS232]
[SerialBaudRate]
[SerialData]
[SerialParity]
[SerialStop]
[SerialFlowControl]
User's Manual
SNMPUsers_Group;
[\SNMPUsers]
For example:
SNMPUsers 1 = v3admin1, 1, 0, myauthkey, -, 1;
The example above configures user 'v3admin1' with security
level authNoPriv(2), authentication protocol MD5,
authentication text password 'myauthkey', and
ReadWriteGroup2.
For more information, see ''Configuring SNMP V3 Users'' on
page 98.
Table 65-6: Serial Parameters
Enables the device's RS-232 (serial) port.
[0] = Enabled
[1] = (Default) Disabled
The RS-232 serial port can be used to change the networking
parameters and view error/notification messages. To establish serial
communication with the device, see ''Establishing a CLI Session'' on
page 88.
Note: For the parameter to take effect, a device reset is required.
Defines the serial communication baud rate.
The valid values include the following: 1200, 2400, 9600, 14400, 19200,
38400, 57600, or 115200 (default).
Note: For the parameter to take effect, a device reset is required.
Defines the serial communication data bit.
[7] = 7-bit
[8] = (Default) 8-bit
Note: For the parameter to take effect, a device reset is required.
Defines the serial communication polarity.
[0] = (Default) None
[1] = Odd
[2] = Even
Note: For the parameter to take effect, a device reset is required.
Defines the serial communication stop bit.
[1] = (Default) 1-bit (default)
[2] = 2-bit
Note: For the parameter to take effect, a device reset is required.
Defines the serial communication flow control.
[0] = (Default) None
[1] = Hardware
1010
Mediant 1000B Gateway & E-SBC
Description
Description
Document #: LTRT-27055