Parameter
Log Destination
log-dest
[LoggingFilters_LogDestination]
User's Manual
"1/2" (without apostrophes), means module 1, port 2
"1/[2-4]" (without apostrophes), means module 1, ports 2
through 4
The exclamation (!) wildcard character can be used for excluding
a specific configuration entity from the filter. For example, to
include all IP Groups in the filter except IP Group ID 2, configure
the 'Filter Type' parameter to IP Group and the 'Value'
parameter to "!2" (without apostrophes). Note that for SBC calls,
a Logging Filter rule applies to the entire session, which is both
legs (i.e., not per leg). For example, a call between IP Groups 1
and 2 are logged for both legs even if the 'Value' parameter is
configured to "!2".
Any to indicate all.
Note:
You can use the index number or string name to specify the
configuration entity for the following 'Filter Types': Tel-to-IP, IP-
to-Tel, IP Group, SRD, Classification, IP-to-IP Routing, or SIP
Interface. For example, to specify IP Group at Index 2 with the
name "SIP Trunk", configure the parameter to either "2" or "SIP
Trunk" (without apostrophes).
For IP trace expressions, see ''Filtering IP Network Traces'' on
page 959.
Defines where the device sends the log file.
[0] Syslog Server = The device generates Syslog messages
based on the configured log filter and sends them to a user-
defined Syslog server. The Syslog messages can contain one of
the following types of information, depending on the settings of
the 'Log Type' parameter (described later):
Not configured (default): Syslog messages include regular
syslog information.
CDR Only: Syslog messages include only CDRs (no system
information and alerts).
[1] Debug Recording Server = (Default) The device generates
debug recording packets based on the configured log filter and
sends them to a user-defined Debug Recording server.
[2] Local Storage = The device generates CDRs based on the
configured log filter and stores them locally on the device. For
more information on local CDR storage, see Storing CDRs on
the Device on page 943.
Note:
If the 'Filter Type' parameter is configured to IP Trace, you must
configure the parameter to Debug Recording Server.
If you configure the parameter to Local Storage, you must
configure the 'Log Type' parameter to CDR Only.
If you configure the parameter to Syslog Server and the debug
level (GwDebugLevel) is configured to No Debug (see
''Configuring Syslog Debug Level'' on page 966), the Syslog
messages include only system Warnings and Errors.
If you configure the parameter to Debug Recording Server, you
can also include Syslog messages in the debug recording
packets sent to the debug recording server. To include Syslog
messages, configure the 'Log Type' parameter (see below) to
the relevant option.