Mechanical Construction - Endress+Hauser iTEMP TMT162 Operating Instructions Manual

Temperature field transmitter
Hide thumbs Also See for iTEMP TMT162:
Table of Contents

Advertisement

iTEMP TMT162
Design, dimensions
Weight
Materials
Endress+Hauser
13.6

Mechanical construction

Dimensions in mm (in)
50
40
30
20
°C
10
0
112 (4.41)
 17
Die-cast aluminum housing for general applications, or optional stainless steel housing (316L)
* Dimensions without display = 112 mm (4.41")
94 (3.7)
50
40
30
20
°C
10
0
 18
Option: T17 stainless steel housing for hygienic applications
• Separate electronics module and connection compartment
• Display attachable in 90° stages
• Aluminum housing approx. 1.4 kg (3 lb), with display
• Stainless steel housing approx. 4.2 kg (9.3 lb), with display
• T17 housing approx. 1.25 kg (2.76 lb), with display
Housing
Die-cast aluminum housing AlSi10Mg/
AlSi12 with powder coating on
polyester base
316L
Stainless steel 1.4435 (AISI 316L) for
hygienic applications (T17 housing)
Display O-ring 88x3: EPDM70, PTFE
anti-friction coating
60
70
80
90
100
Sensor terminals
Nickel-plated brass 0.3 µm
gold flashed / cpl.,
corrosion-free
-
Technische Daten
132.5 (5.22)*
114 (4.49)
Nameplate
Aluminum AlMgl, anodized in black
1.4404 (AISI 316L)
-
-
A0024608
A0024609
59