Endress+Hauser iTEMP TMT162 Operating Instructions Manual page 55

Temperature field transmitter
Hide thumbs Also See for iTEMP TMT162:
Table of Contents

Advertisement

iTEMP TMT162
Designation
Standard
Ni100 (6)
DIN 43760
IPTS-68
Ni120 (7)
Cu50 (10)
OIML R84:
2003 /
Cu100 (11)
GOST
6651-2009
Ni100 (12)
Ni120 (13)
OIML R84:
Cu50 (14)
2003 /
GOST 6651-94
Resistance transmitter (Ω)
10 to 400 Ω
10 to 2000 Ω
1)
Measured value transmitted via HART
2)
Percentages based on the configured span of the analog output signal
Influence of ambient temperature and supply voltage on operation for thermocouples (TC) and voltage transmitters
Designation
Standard
Type A (30)
IEC 60584-1
Type B (31)
IEC 60584-1 /
Type C (32)
ASTM E988-96
Type D (33)
ASTM E988-96
Type E (34)
Type J (35)
Type K (36)
IEC 60584-1
Type N (37)
Type R (38)
Type S (39)
Type T (40)
Type L (41)
DIN 43710
Type U (42)
Endress+Hauser
Ambient temperature:
Influence (±) per 1 °C (1.8 °F) change
≤ 0.004 °C
(0.007 °F)
≤ 0.007 °C
(0.013 °F)
0.002% * (MV - LRV),
at least 0.004 °C (0.007 °F)
≤ 0.004 °C
(0.007 °F)
≤ 0.007 °C
(0.013 °F)
0.0015% * (MV - LRV),
≤ 6 mΩ
at least 1.5 mΩ
≤ 30 mΩ
0.0015% * (MV - LRV),
at least 15 mΩ
®
.
Ambient temperature:
Influence (±) per 1 °C (1.8 °F) change
1)
Digital
Maximum
Based on measured value
≤ 0.13 °C
0.0055% * (MV - LRV),
(0.23 °F)
at least 0.03 °C (0.054 °F)
≤ 0.06 °C
(0.11 °F)
0.0045% * (MV - LRV),
at least 0.03 °C (0.054 °F)
≤ 0.08 °C
(0.14 °F)
0.004% * (MV - LRV),
at least 0.035 °C (0.063 °F)
≤ 0.03 °C
0.003% * (MV - LRV),
(0.05 °F)
at least 0.016 °C (0.029 °F)
0.0028% * (MV - LRV),
at least 0.02 °C (0.036 °F)
≤ 0.04 °C
0.003% * (MV - LRV),
(0.07 °F)
at least 0.013 °C (0.023 °F)
0.0028% * (MV - LRV),
at least 0.020 °C (0.036 °F)
0.0035% * (MV - LRV),
≤ 0.05 °C
at least 0.047 °C (0.085 °F)
(0.09 °F)
≤ 0.01 °C
(0.02 °F)
≤ 0.02 °C
(0.04 °F)
≤ 0.01 °C
(0.02 °F)
-
≤ 0.005 °C
(0.009 °F)
-
≤ 0.008 °C
-
(0.014 °F)
≤ 0.004 °C
-
(0.007 °F)
-
≤ 0.008 °C
-
(0.014 °F)
0.001 %
≤ 30 mΩ
2)
D/A
Maximum
≤ 0.07 °C
(0.13 °F)
≤ 0.06 °C
-
(0.11 °F)
≤ 0.04 °C
(0.07 °F)
≤ 0.02 °C
(0.04 °F)
0.001 %
≤ 0.05 °C
(0.09 °F)
-
-
≤ 0.01 °C
-
(0.02 °F)
-
Supply voltage:
Influence (±) per V change
-
-
-
0.002% * (MV - LRV),
at least 0.004 °C (0.007 °F)
-
-
-
0.0015% * (MV - LRV),
≤ 6 mΩ
at least 1.5 mΩ
0.0015% * (MV - LRV),
at least 15 mΩ
Supply voltage:
Influence (±) per V change
Digital
Based on measured value
0.0054% * (MV - LRV),
at least 0.02 °C (0.036 °F)
-
0.0045% * (MV - LRV),
at least 0.03 °C (0.054 °F)
0.004% * (MV - LRV),
at least 0.035 °C (0.063 °F)
0.003% * (MV - LRV),
at least 0.016 °C (0.029 °F)
0.0028% * (MV - LRV),
at least 0.02 °C (0.036 °F)
0.003% * (MV - LRV),
at least 0.013 °C (0.023 °F)
0.0028% * (MV - LRV),
at least 0.020 °C (0.036 °F)
0.0035% * (MV - LRV),
at least 0.047 °C (0.085 °F)
-
-
-
-
Technische Daten
0.001 %
D/A
0.001 %
55

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents