04/96
Key
Acknowledgement
Reset
POWER ON
POWER ON means switching off the control and switching it on again.
Please note the information provided by the machine tool manufacturer.
Siemens AG 2001 All rights reserved 6FC5198–jAB40
SINUMERIK 840C / SIMODRIVE 611–D (DA)
Effect of cancelling alarms
An active NC program is not aborted but only stopped.
After eliminating the error, it is possible to continue execution of the NC pro-
gram from the point at which it was stopped.
Execution of an active NC program is aborted. After eliminating the error, the
NC program must be restarted.
Execution of the active NC program is aborted. After eliminating the error, the
NC program must be restarted and the reference points must be reapproa-
ched.
Caution! On switching off the control, the contents of the NCK part program
memory are lost.
1.2 Alarm numbers/cancellation of alarms
1 Alarms
1–3