1 Alarms
1.5.1 Alarm description
160067
Timeout
Scan
Startup application
Effect
Startup function is not executed
Explanation
Timeout error on internal communication
Remedy
End application and restart
160068
Illegal amplitude
Scan
Function generator or measuring function parameterization
Effect
Function cannot be started
Explanation
The defined amplitude is illegal
Remedy
Enter sensible amplitude value
160069
Illegal amplitude 1
Scan
Function generator parameterization (square wave)
Effect
The function cannot be started
Explanation
The stated amplitude is illegal
Remedy
Enter sensible amplitude value
160070
Illegal amplitude 2
Scan
Function generator parameterization (staircase)
Effect
Function cannot be started
Explanation
The stated amplitude is illegal
Remedy
Enter sensible amplitude value
160071
Illegal bandwidth
Scan
Function generator/measuring function parameterization
Effect
Function cannot be started
Explanation
The bandwidth must be <= of half the sampling rate
Remedy
Set permissible bandwidth
160072
Illegal scaling
Scan
Function generator/measuring function parameterization
Effect
The function cannot be started
Explanation
–
Remedy
Set permissible scaling
160073
Illegal period duration
Scan
Function generator/measuring function parameterization
Effect
The function cannot be started
Explanation
–
Remedy
Enter a sensible value not equal to zero
160074
Illegal limitation
Scan
Function generator/measuring function parameterization
Effect
The function cannot be started
Explanation
–
Remedy
Enter a lower value not equal to zero