Siemens Sinumerik 840C Diagnostics Manual page 162

Digital ana module
Hide thumbs Also See for Sinumerik 840C:
Table of Contents

Advertisement

1 Alarms
1.5.1 Alarm description
160067
Timeout
Scan
Startup application
Effect
Startup function is not executed
Explanation
Timeout error on internal communication
Remedy
End application and restart
160068
Illegal amplitude
Scan
Function generator or measuring function parameterization
Effect
Function cannot be started
Explanation
The defined amplitude is illegal
Remedy
Enter sensible amplitude value
160069
Illegal amplitude 1
Scan
Function generator parameterization (square wave)
Effect
The function cannot be started
Explanation
The stated amplitude is illegal
Remedy
Enter sensible amplitude value
160070
Illegal amplitude 2
Scan
Function generator parameterization (staircase)
Effect
Function cannot be started
Explanation
The stated amplitude is illegal
Remedy
Enter sensible amplitude value
160071
Illegal bandwidth
Scan
Function generator/measuring function parameterization
Effect
Function cannot be started
Explanation
The bandwidth must be <= of half the sampling rate
Remedy
Set permissible bandwidth
160072
Illegal scaling
Scan
Function generator/measuring function parameterization
Effect
The function cannot be started
Explanation
Remedy
Set permissible scaling
160073
Illegal period duration
Scan
Function generator/measuring function parameterization
Effect
The function cannot be started
Explanation
Remedy
Enter a sensible value not equal to zero
160074
Illegal limitation
Scan
Function generator/measuring function parameterization
Effect
The function cannot be started
Explanation
Remedy
Enter a lower value not equal to zero
1–154
Siemens AG 2001 All rights reserved 6FC5198–jAB40
SINUMERIK 840C / SIMODRIVE 611–D (DA)
04/96
OK softkey
OK softkey
OK softkey
OK softkey
OK softkey
OK softkey
OK softkey
OK softkey

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-dSinumerik 840ce

Table of Contents