Siemens Sinumerik 840C Diagnostics Manual page 111

Digital ana module
Hide thumbs Also See for Sinumerik 840C:
Table of Contents

Advertisement

04/96
105006
System crash – Please switch control off/on
105006
!!! System crash – reboot !!!
Scan
Power up
Effect
MMC is rebooted after 5 seconds
Explanation
Either applications or the operating system has crashed or there is an MMC hardware fault
Remedy
POWER ON
105007
Operator system initialization failed
Scan
Power up
Effect
No power up of MMC
Explanation
Internal system error during power up
Remedy
Inform system service
105008
Hardware error: ...
Scan
Effect
Alarm 105006 is also output ––> see alarm 105006
Explanation
DPR driver recognizes NMI because of a MMC hardware error: I/O channel check error or RAM parity error
Remedy
POWER ON
UMS too large ³ UMS not loaded
105009
Scan
Power up
Effect
UMS does not load
Explanation
The UMS (customer or Siemens UMS) cannot be loaded with the current memory configuration because it is set
greater than in NC–MD 60000 (as from SW 4; up to SW 3, 512 kB fixed).
Remedy
Change the memory configuration (as from SW 4); set MD 60000 accordingly.
105010
Master control initialization failed!
Scan
Power up
Effect
No power up of MMC
Explanation
Internal system error during power up
Remedy
Inform system service
105011
Internal error: ...
Scan
Effect
Alarms 105002, 105012 or 105013 are also output ––> see these alarms
Explanation
Internal system error
Remedy
See alarms 105002, 105012 and 105013
Error in UMS ³ UMS not loaded
105012
Scan
Power up
Effect
UMS does not load
Explanation
More detailed error diagnostics are entered in the log with message 105011
Remedy
Check customer UMS, POWER ON
Siemens AG 2001 All rights reserved 6FC5198–jAB40
SINUMERIK 840C / SIMODRIVE 611–D (DA)
1 Alarms
1.5.1 Alarm description
POWER ON
POWER ON
POWER ON
OK softkey
POWER ON
OK softkey
OK softkey
1–103

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-dSinumerik 840ce

Table of Contents