Siemens Sinumerik 840C Diagnostics Manual page 198

Digital ana module
Hide thumbs Also See for Sinumerik 840C:
Table of Contents

Advertisement

1 Alarms
1.5.1 Alarm description
Error No.
F...
F044 (drive SW
2.5 and higher)
F045
F046
Note
Applies as from SW 3
300501
Current monitoring
Scan
Cyclically after the control is switched on
Effect
Pulse reset, motor coasts down
SIMODRIVE READY and DRIVE_READY are reset.
Power On error.
Explanation
1. The smoothed current amount (smoothing time: MD 1254) is greater than or equal to a current threshold.
A serious error has occurred in the current actual value acquisition.
2. With active rotor position identification (FDD only), the permissible current threshold has been exceeded.
S
Up to SW 2.6 (611–D): only MSD; additionally to alarms 300502 / 300503
Current threshold = 1,2 * max. permissible power section current (MD1107)
S
With SW 2.6 and higher: FDD and MSD; replacing alarms 300502 / 300503
Current threshold = 1,2 * 1,05 * max. permissible power section current (MD1107)
Remedy
Check maximum power section current MD1107; replace 611D hardware if necessary
Note
Applies with SW 3 and higher
300502
Meas. circuit error phase current R
Scan
Cyclic after control power up
S
Effect
Pulse suppression, motor runs down
S
SIMODRIVE_READY and DRIVE_READY are cancelled.
S
Power On error
Explanation
Phase current R is greater than or equal to 1.05 times the value of the maximum permissible power section current
MD 1107. Serious error has occurred in the actual current value circuit.
S
Check maximum power section current MD1107
S
Defective actual current value circuit
Remedy
Check maximum power section current MD1107; replace 611D hardware if necessary
Note
Applies up to SW 4 (611–D: up to SW 2.6)
1–190
Additional
Explanation
information
(xx = for diagno-
stic purposes)
S
xx /axis no.
The rotor position synchroniza-
tion is faulty. The difference
between the first part of rotor
position synchronization
(coarse synchronization) and
the second part (fine synchro-
nization to the active encoder
zero mark) exceeds45_electri-
cal. A too large difference may
be caused by the following:
incorrect encoder adjustment
EMC problem on zero mark
signal
too high voltage level of CD
track
Error code / Axis
Either an encoder with distance-co-
No.
ded reference marks has been ent-
ered by the NC or a BERO switch in
the register $1D of the motor mea-
suring system of the PCU ASIC.
This is not allowed during fine syn-
chronization which is activated by
powering up, by zero monitoring er-
ror or by deselecting the parking
axis.
xx / xx
As from drive software SW 4.02,
startup of the drive is only possible
with the drive software loaded
Siemens AG 2001 All rights reserved 6FC5198–jAB40
Remedy
S
Check encoder adjustment and
EMC measures
new sequence
check mode
replacee motor
After powering up, in the event of
zero monitoring errors or after dese-
lection of the parking axis, the NC/
PLC must not enter encoders with
distance-coded reference marks or
a BERO switch into the register $1D
of the motor measuring system of
the PCU ASIC.
Re-load drive software
SINUMERIK 840C / SIMODRIVE 611–D (DA)
04/96
07/97
Relevant for
FDD
FDD / MSD
FDD/MSD
POWER ON
POWER ON

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-dSinumerik 840ce

Table of Contents