1 Alarms
1.5.1 Alarm description
Error No.
F...
F010
F011
F012
F013
F014
F015
F016
F017
F018
F019
1–188
Additional
Explanation
information
(xx = for diagno-
stic purposes)
x / xx
The boundaries of the processor-in-
x =
ternal hardware stack or of the soft-
1: HW undeflow
ware-stack in the data memory have
2: HW overflow
been violated.
3: SW underflow
4: SW overflow
xx / xx
The watchdog timer on the servo
control module has expired. Caused
by a hardware fault in the time base
on the servo control module.
xx / xx
The NC basic clock pulse generated
on the NC and transferred via the
drive bus cable to the drive has fai-
led. Possible causes: NCK Reset,
EMC faults, hardware fault NC, ca-
ble break drive bus, hardware fault
servo control module.
xx / xx
The NC basic clock pulse generated
on the NC and transmitted via the
drive bus cable to the drive did not
supply a pulse that fits in the clock
pulse grid. Possible causes: EMC
faults drive bus, hardware fault NC,
hardware fault servo control mo-
dule.
Incorrect
The processor has detected an ille-
address / xx
gal command in the program me-
mory.
xx / xx
In the continuous checking of the
As from version
checksum in the program memory, a
4.0: start address
difference has been found between
of the incorrect
the set and actual checksums. Pre-
code data area
sumably caused by a hardware fault
As from version
on the servo control module.
4.0: segment of
the incorrect
code data area,
with:
0: P memory
1: X memory
2: Y memory
xx / xx
An illegal interrupt of the processor
has occurred.
xx / xx
An illegal interrupt of the processor
has occurred.
xx / xx
An illegal interrupt of the processor
has occurred.
xx / xx
An illegal interrupt of the processor
has occurred.
Siemens AG 2001 All rights reserved 6FC5198–jAB40
Remedy
Reload drive software.
Replace servo control module.
Replace servo control module.
Check drive bus cable and plug-on
connectors, take measures to elimi-
nate noise (screening, check
ground connections), replace NC
hardware, replace servo control mo-
dule.
Check drive bus cable and plug-on
connectors, take measures to elimi-
nate noise (screening, check
ground connections), replace NC
hardware, replace servo control mo-
dule.
Replace servo control module.
Replace servo control module.
Check drive bus cable and connec-
tor.
Replace servo control module.
Check drive bus cable and connec-
tor.
Replace servo control module.
Check drive bus cable and connec-
tor.
Replace servo control module.
Check drive bus cable and connec-
tor.
Replace servo control module.
SINUMERIK 840C / SIMODRIVE 611–D (DA)
04/96
08/96
Relevant for
FDD / MSD
FDD / MSD
FDD / MSD
FDD / MSD
FDD / MSD
FDD / MSD
FDD / MSD
FDD / MSD