04/96
106004
...: This data area on-line only
Scan
File functions MDD with user pictures.
Effect
This function is not possible.
Explanation
The selected data area can only be combined with data block selection 0 (i.e. always on-line). Storage on harddisk
in punched tape format is not possible.
Remedy
Correct the error as far as possible and repeat the process.
Note
Applies as from SW 4
106005
Memory overflow
Scan
File functions MDD
Effect
Function is aborted
Explanation
The main memory (RAM) is full
Remedy
End another application and repeat the process.
Note
Applies as from SW 4
106006
Harddisk full
Scan
File functions MDD
Effect
Function is aborted
Explanation
The harddisk is full
Remedy
Delete another file and repeat the process.
Note
Applies as from SW 4
106007
MD error: ...
Scan
Individual fields with machine data
Effect
Function is aborted
Explanation
Input or configuring error
Remedy
Note
Applies as from SW 4
110000
No data can be created here
Scan
FUNCTION / NEW
Effect
Explanation
No new data can be created by the user in the current directory
Remedy
Select another directory
110001
Please enter correct name
Scan
MANAGEMENT / COPY / PASTE / OK
Effect
Explanation
The entered name can only contain letters, numbers or underline. For part program %3 = MPF3<3 = SPF3. The
length of the file name must be no more than 8 characters.
Remedy
Correct the name
110002
Name ... already exists
Scan
COPY / PASTE
Effect
Explanation
The entered name already exists for the data type
Remedy
Enter a different name
Siemens AG 2001 All rights reserved 6FC5198–jAB40
SINUMERIK 840C / SIMODRIVE 611–D (DA)