04/96
2068*
Link factor KF illegal
Scan
When entering a new link factor via G function (from NCK).
S
Effect
Command is not executed, the previous link factor is maintained
S
Interlocking of NC START
Explanation
Denominator J=0 programmed
Remedy
Correct link factor
Note
Applies as from SW 3
2069*
Overwriting of position not allowed
Scan
When programming a position with GI command.
S
Effect
G command not executed
S
Interlocking of NC START
Explanation
GI positions must not be overwritten (enable with MD 525*, bit 3)
Remedy
Correct input
Note
Applies as from SW 3
2070*
Reconfiguration/deletion not allowed
Scan
At RECONFIGURATION via G function (G401), i.e. addition, cancellation of a leading spindle or changing a cou-
pling structure or on DELETE CONFIGURATION (from NCK).
Effect
Interlocking of NC START; NC Stop, stopping of the channel, command is not executed, JOG mode still possible.
Explanation
A RECONFIGURATION or DELETE CONFIGURATION is not allowed without being preceeded by LINK_OFF.
Reconfiguration not allowed (MD 525, bit 1)
New configuration block; following spindle already exists
Remedy
Precede by LINK_OFF for the specified GI combination.
2073*
Change of link factor KF illegal
Scan
When entering a new link factor with G function (from NCK).
Effect
Command is not executed, the previous link factor is maintained. Interlocking of NC Start; NC Stop, channel stop-
ped: JOG mode still possible.
Explanation
The link factor entered is not in the range 0.00000001 <= /KF/ <= 10.000000 or denominator J=0 or the individual
values are so large that internal overflows occur.
Remedy
Correct the link factor KF.
2074*
Change of link factor KF not allowed
Scan
When entering a new link factor with G function (from NCK).
S
Effect
Command is not executed, the previous link factor is maintained
S
Interlocking of NC START
S
NC STOP
S
Channel is stopped: JOG mode still possible
Explanation
The link factor must not be switched over from the default setting (MD525*).
Remedy
Change default setting if necessary.
Siemens AG 2001 All rights reserved 6FC5198–jAB40
SINUMERIK 840C / SIMODRIVE 611–D (DA)
1 Alarms
1.5.1 Alarm description
Acknowledgement key
Acknowledgement key
Reset key
Reset key
Reset key
1–89