1 Alarms
1.5.1 Alarm description
110047
Interface is still active
Scan
Effect
A data transmission session to this interface has not yet ended.
Explanation
Remedy
Terminate data transmission.
Note
Applies as from SW 4.4
110048
Interface signals overrun
Scan
DATA IN-OUT / DATA INPUT / START
Effect
Data are not read in correctly
Explanation
Hardware problem
Remedy
110049
Check interface parameterization
Scan
DATA IN-OUT / DATA INPUT / START
Effect
Data are not read in correctly
Explanation
Baud rate, parity, data length, number of stop bits incorrect
Remedy
Alter interface data and reselect
110049
V24: Check interface parameters
Scan
Serial communication via V24
Effect
Data are not read in correctly.
Explanation
If the transfer is interrupted in order to request the operator whether an already existing file is to be overwritten and
if no transfer protocol (e.g. RTS/CTS) has been defined, the transfer is interrupted and this message output.
Remedy
Set type of protocol and select again.
Note
Alarm from SW 6.3
110050
Floppy is already full
Scan
DATA IN-OUT / DATA OUTPUT / ... / START
(INSERT NEXT DISKETTE) OK
Effect
Data are not are not archived
Explanation
A full diskette has been inserted
Remedy
Insert new diskette
110051
... was not printed
Scan
DATA IN-OUT / PRINT SERIAL / START
Effect
Not all of the specified object has been printed or it has not been printed at all
Explanation
None
Remedy
Check interface/printer
110052
... signals timeout
Scan
(DATA INPUT OR OUTPUT)
Effect
Data have not been read in or read out
Explanation
No data were read in or collected in the parameterized time (TIMEOUT)
Remedy
Check other station
110053
End of transmission without end identifier
Scan
DATA IN-OUT / ... / ... / START
Effect
Data are not read-in/written or only partially
Explanation
E.g. end of data without M02 or end identifier
Remedy
Check other station and cable
1–116
Siemens AG 2001 All rights reserved 6FC5198–jAB40
SINUMERIK 840C / SIMODRIVE 611–D (DA)
04/96
09/01
OK softkey
OK softkey
OK softkey
OK softkey
OK softkey
OK softkey
OK softkey

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-dSinumerik 840ce

Table of Contents