1 Alarms
1.5.1 Alarm description
160082
Illegal signal type
Scan
Function generator parameterization
Effect
The function cannot be started
Explanation
The selected function is not possible with this signal
Remedy
Change signal type
160083
Value not allowed
Scan
Startup application
Effect
The function is not executed
Explanation
The value concerned is not within the permissible value range (negative acknowledgement with variables service)
Remedy
Correct input
160084
Value > maximum value
Scan
Function generator/measuring function parameterization
Effect
The function cannot be started
Explanation
The value in question exceeds the permissible maximum value
Remedy
Enter lower value
160085
Value < minimum value
Scan
Function generator/measuring function parameterization
Effect
The function cannot be started
Explanation
The value in question is below the permissible minimum value
Remedy
Enter larger value
160086
Max. acceleration too large
Initialization value too large
Fine quantization too large
Number of learning runs too large
S
Scan
Reparameterization of the maximum acceleration (function parameters of the neural quadrant error compensa-
tion)
S
Reparameterization of the initialization value (function parameters of the neural quadrant error compensation)
S
Reparameterization of the fine quantization (function parameters of the neural quadrant error compensation)
S
Reparameterization of the number of learning runs (function parameters of the neural quadrant error compen-
sation)
Effect
Start-up function aborts
S
Explanation
a) The maximum working area has been entered as a value that is greater than allowed in MD 276* and the
function generator has been started with this.
b) The maximum working area exceeds internal format limits (even without function generator start)..
S
The initialization value of the neural quadrant error compensation is limited to 1% of the maximum speed in
order to prevent uncontrolled injections during the learning phase if the network has not yet established the
characteristic. In the 1st learning run, this value is used as injection amplitude.
S
The fine quantization must be greater than/equal to 4 and less than/equal to 32.
S
The number of learning runs must not be less than 5 or greater than 40.
S
Remedy
Enter a smaller value in the function parameter max. acceleration.
S
Enter a value between 0 and 1% (resolution 0.001%).
S
Enter a valid value in the fine quantization.
S
Enter a valid value.
1–156
Siemens AG 2001 All rights reserved 6FC5198–jAB40
SINUMERIK 840C / SIMODRIVE 611–D (DA)
04/96
OK softkey
OK softkey
OK softkey
OK softkey
OK softkey

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-dSinumerik 840ce

Table of Contents