04/96
130016
No more memory space available
Scan
NEW / CREATE
Effect
Directory/file cannot be created
Explanation
No memory left to create the directory/file
Remedy
Workpieces/files which are no longer required can be deleted
130017
Disk full! No graphical programming
Scan
PROGRAMMING
Effect
Workpiece cannot be machined
Explanation
No memory available to load programming system data
Remedy
Workpieces/files which are no longer required can be deleted
130018
File not available
Scan
EMPIRICAL VALUES
Effect
Empirical values file cannot be processed
Explanation
There is no empirical value file in the data management tree that can be copied into the user branch for
processing.
Remedy
Notify service
130019
Data transfer in progress! Terminate?
Scan
Effect
Explanation
If an MMC CPU with 8 MB is available, the graphic programming system (WOP) must not be started while the V24
data transfer is in progress.
S
Remedy
By pressing the OK softkey, the V24 data transfer is aborted.
S
By pressing the ABORT softkey, WOP is not started.
Note
Applies as from SW 4.4
130020
File has been altered! Lose change?
Scan
Effect
Explanation
File was exited after an alteration with RECALL and without softkey SAVE.
S
Remedy
Press ABORT softkey if further changes are to be made in the edit mode.
S
Press OK softkey if the changes are to be lost.
Note
Applies as from SW 4.4
Siemens AG 2001 All rights reserved 6FC5198–jAB40
SINUMERIK 840C / SIMODRIVE 611–D (DA)
1 Alarms
1.5.1 Alarm description
OK softkey
OK softkey
OK softkey
Abort/OK softkey
Abort/OK softkey
1–131