1 Alarms
1.5.1 Alarm description
100008
... (Alarm text is variable)
Scan
Effect
Special error text
Explanation
Explained by context of operation
Remedy
100009
The area ..... is terminated
Scan
Effect
Explanation
Remedy
100202
Error in file structure <%1>
Scan
Data management during job list processing
Effect
Processing job lists interrupted
Explanation
Error in job list (workpiece does not exist, file opening/closing error)
Remedy
Correct job list
Note
Alarm from SW 6.3
100203
Timeout when executing an application in the job list
Scan
Data management while executing the CALL command in the job list.
Effect
The called application checks back within the WAIT time. Execution of the job list is aborted.
Explanation
In the job list you have implemented a CALL instruction to initiate an MMC application. The WAIT parameter forms
a part of this CALL instruction. If the application does not check back properly within the projected time frame (file
sin840c.ini, Section Datenman, Entry Timeout), the forenamed alarm is issued.
Remedy
Check the CALL instruction in the job list to verify that the path and application name are correct. Ascertain
whether the application is available on the MMC disk.
Note
Alarm from SW 6.3
100204
File <%1> not transferred
Scan
Data management while executing the LOAD command in the job list or if file transfer is initiated in an application
with I–Code 421.
Effect
File is not transferred.
Explanation
This error occurs in case of incorrect syntax when several part programs are being transferred.
Example: Comma omitted in MPF[1,999], i.e. entered as MPF[1999]
Remedy
Correct the syntax
Note
Alarm from SW 6.3
100205
Copying active <%1>
Scan
Data management on inch/metric changeover
Effect
None
Explanation
When the inch/metric changeover is initiated, a message is issued to indicate that the relevant machine data are
being loaded.
Remedy
Not applicable
Note
Alarm from SW 6.3
100206
Workpiece <%1> does not exist
Scan
In the data management with "Reload workpiece upon Power On"
Effect
Workpiece cannot be loaded into the NC.
Explanation
This message is output if the workpiece to be loaded is not found (e.g. workpiece has been deleted on the MMC
disk or incorrect network connection).
Remedy
Copy workpiece back to the MMC disk or establish network connection.
Note
Alarm from SW 6.4
1–94
Siemens AG 2001 All rights reserved 6FC5198–jAB40
SINUMERIK 840C / SIMODRIVE 611–D (DA)
04/96
09/01
01/99
OK softkey
OK softkey