165077
Pole pair no. (ratio MD x130/MD x400) illegal
Scan
Softkey "Calculate controller data (MSD only)"
Effect
The controller data have been calculated, the machine data concerned has been given a suitable default value.
Explanation
The pole pair no. (ratio rated frequency (MD 1134 and MD 2134) / rated speed (MD 1400 and MD 2400) is illegal.
Remedy
If necessary, correct value and repeat function.
Note
Applies as from SW 5.4
165078
MIC %1
Scan
In the machine data dialog (MDD) when softkey "Start conversion" is pressed
Effect
The target data record is not created.
Explanation
An error (e.g. syntax error) has occurred in the configuration file that belongs to the metric/inch conversion. The
error message contains a line number and a description of the cause of the error or only a general error text that
cannot be assigned to a specific line number.
Remedy
Eliminate the error in the configuration file (see conversion data in file CONFIG).
Note
Alarm from SW 6.3
300000
System error
Scan
Cyclic after control startup
Effect
Machining stops, interlocking of NC Start and Mode Group Ready
Explanation
Additional
Additional
information 1
information 2
(error no.)
0x0001
Task ID
0x0002
Task ID
0x0003
Task ID
0x0004
Task ID
0x0011
Protocol ID
0x0012
Message
frame type
0x0013
Service ID
0x0014
Variable length Unknown protocol variable length
0x0022
Task ID
0x0023
Pointer
(set/actual)
0x0102
Version
(set/actual)
0x0103
Length
(set/actual)
0x0301
Status
0x0302
Status
0x0303
Status
0x0304
Status
0x0401
Drive no.
0x0402
Message
frame type
0x0403
Message
frame type
0x0404
0x0405
0x0406
0x0407
Siemens AG 2001 All rights reserved 6FC5198–jAB40
SINUMERIK 840C / SIMODRIVE 611–D (DA)
Explanation
Opcode received unknown
Message received unknown
Faulty buffer type
No queues available
Unknown protocol ID
Unknown protocol message type
Unknown protocol service ID
Incorrect NC/servo/drive address
Put_message pointer error
Version error of boot files
Incorrect length of boot files
PI service initialization error
PI service execution error
PI service message error
PI service abort error
Command with illegal drive no.
Command with illegal header
(transmission)
Command with illegal header (reception)
Management overflow on transmitting or-
ders
Management overflow on transmitting of
acknowledgements
Management overflow on receiving orders
Management overflow on receiving
acknowledgements
1 Alarms
1.5.1 Alarm description
OK softkey
POWER ON
Remedy
Contact service
Contact service
Contact service
Contact service
Contact service
Contact service
Contact service
Contact service
Contact service
Contact service
Create boot files again
Create boot files again
Contact service
Contact service
Contact service
Contact service
Contact service
Contact service
Contact service
Contact service
Contact service
Contact service
Contact service
1–179

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-dSinumerik 840ce

Table of Contents