Connecting to the Door Open Button
Connect the wires from the door open button to the terminal block on the door module.
You can either connect the wires to Pin 8 and 9 (Door 1) or Pin 24 and 25 (Door 2) on the
terminal block.

2.2.4 Connecting to the Fire Alarm/ Alarm Input

You can either connect the alarm inputs to the main module or the alarm module.
• On the Main Module
The main module provides two general alarm inputs, connecting to Pin 1 and 2 or Pin
2 and 3 on the terminal block. The GND terminal is shared by these two input signals.
Both inputs can be configured as either fire alarm input or general alarm input.
1 2
• On the Alarm Module
The alarm modules provide 8 alarm inputs. The alarm input pins provided by the
alarm module includes Pin 1, 3, 4, 6, 19, 21, 22, 24. For details on pin assignment,
please refer to 1.6.2 Terminal Block and LEDs on Alarm Module. Following is an
example on connecting the alarm input to the alarm module.
Input Signal
24
8
25
9
Door module
Figure 2-12
Main Module
Figure 2-13
1
2
Alarm module
Figure 2-14
20
EXIT
GND
Alarm Sensor
GND
Alarm Input
Alarm input
GND
Alarm sensor
NAV IP Access Controller