Alarm Action - EverFocus EFC304 User Manual

Nav ip access controller
Hide thumbs Also See for EFC304:
Table of Contents

Advertisement

Input Mode: indicates the alarm input mode.
Disabled: the defence alarm input is invalid.
Normally Open: this input opened in normal state, alarm input enabled after closing.
Normally Close: this input closed in normal state, alarm input enabled after being opened.
Output Mode: the mode that the alarm output responds to the input when an alarm occurs.
Launch: when alarm input is triggered, the alarm output is activated at once; no matter
the alarm input stops or not, alarm output continues until the alarm duration is over.
Transparent: when alarm input is triggered, the alarm output is activated at once; after
alarm input stops, the alarm output stops immediately. At this time, alarm duration
(delay time) does not work.
Alarm Duration: set up a delay duration time for the alarm input to trigger. When an alarm
input event occur, the alarm input will only be triggered until the setup delay time.
Arm Delay: set up a duration time for the alarm outputs to be triggered. When an alarm
input is triggered, the corresponding alarm relay outputs will be triggered based on the
setup duration time.
Action Doors: select the door(s) respond to the alarm input.
Steps:
1) Click the "Alarm Input" tab.
2) Select the alarm input which needs to be set.
3) Input alarm input information.
4) Click the "Save" button to save your changes.

12.1.4 Alarm Action

On the alarm action settings page, users can configure the alarm output, including: the
main modules output, door module output and alarm module output etc.
Figure12-5 Alarm Action
104
NAV IP Access Controller