Invalid Time: Each card belongs to an access group. For each group, the system can
assign access rights to certain doors for certain time zones. An invalid time event will
be generated if a card is swiped during a time period in which it does not have the
right to pass. The controller generates alarm output(s) according to the setting in the
"Invalid Time" column.
APB Fail: If the card APB property is enabled, and door behavior under APB is set to
"unlock". A cardholder will be able to enter/exit any doors by swiping the card. The
system generates an APB fail event if an APB event is triggered. The controller
generates alarm output(s) according to the setting in the "APB Fail" column.
Card PIN Fail: A card PIN fail event is generated when a PIN-enabled card is presented
at a reader and an incorrect PIN is entered three times consecutively. The controller
generates alarm output(s) according to the setting in the "Card PIN Fail" column.
Door Forced Open: A door forced open event is generated when the door sensor
indicates to the controller that a door is opened, but no legitimate card has been
presented and a Request-to-Exit button has not been pressed. The controller
generates alarm output(s) according to the setting in the "Door Forced Open". In
practice, a door forced open event will be generated if a door is kicked open.
Door endures Open: A door endures open event is generated if a cardholder enters
endures PIN to unlock a door when under endures. The controller generates alarm
output(s) according to the setting in the "Door endures Open".
Door Held Open/Overtime: the system keeps tracking of the door status when a card
is presented to a reader or Request-to-Exit button is pressed. A door held
open/overtime event occurs when a door is held open for longer than the allowed
door held open time. The controller generates alarm output(s) according to the
setting in the "Door Held Open" column.
Reader Lost: A reader lost event is generated when the controller detects that the
card reader appears to have been disconnected from the system. The controller
generates alarm output(s) according to the setting in the "Reader Lost" column.
Panic door: When an access denied appears and request open did not implement,
however, door magnetic sensor is displayed the door have been opened, it will lead a
"panic door" event. The controller generates alarm output(s) according to the setting
in the "Panic Door" column.
Steps:
1) Click the "Alarm Action" tab.
2) Select an alarm to be set in the alarm list.
3) In the corresponding, click the position to show drop-down menu of alarm output,
select the output value: R, Y, N.
4) Click the "Save" button to save your changes.