Fire Alarm: A fire alarm event is generated when there is a fire alarm input. The
controller generates an alarm output according on the setting in the "Fire Alarm"
column.
Zone Alarm: The zone alarm reacts to 8 alarm inputs on the alarm module. Any
events in the arm zone may trigger a zone alarm event. The controller generates an
alarm output according on the setting in the "Zone Alarm" column.
System PIN Fail: User is required to enter system PIN to enter to the system setting
menu. If an incorrect system PIN is entered three times consecutively, the system will
generate a "system PIN fail" event. The controller generates alarm output(s)
according to the setting in the "system PIN fail" column.
ARM PIN Fail: User is required to enter ARM PIN when pressing the "ARM" key on the
controller to arm/disarm the system. If an incorrect ARM PIN is entered three times
consecutively, the system will generate an "ARM PIN fail" event. The controller
generates alarm output(s) according to the setting in the "ARM PIN fail" column.
Tamper Alarm: A tamper alarm event will be generated if there is a temper alarm
input. The controller generates alarm output(s) according to the setting in the
"Tamper Alarm" column.
Remote Alarm: A system administrator can directly generate alarm signals using the
control software when he observes an abnormal condition through a surveillance
system. This is defined as a Remote Alarm event. The controller generates alarm
output(s) according to the setting in the "Remote Alarm" column.
Unknown Card: unknown card refers to a card that is never enrolled in the system.
An unknown card event will be generated when an unknown card is presented to any
reader. The controller generates alarm output(s) according to the setting in the
"Unknown Card" column.
Expired Card: any card in the system is usually assigned a valid date. After the valid
date passes, the controller will automatically set the card as an expired card. An
expired card cannot gain access to the system. An expired card event will be
generated if an expired card is swiped on the reader. The controller generates alarm
output(s) according to the setting in the "Expired Card" column.
Invalid Card: User can directly set a card as an invalid card to disable the card. An
invalid card cannot gain access to the system. An invalid card event will be generated
if an invalid card is swiped on the reader. The controller generates alarm output(s)
according to the setting in the "Invalid Card" column.
Invalid Door: Each card belongs to an access group. For each group, the system can
assign access rights to certain doors for certain time zones. An Invalid Door event will
be generated when a card is swiped at any door at which it does not have the right to
pass. The controller generates alarm output(s) according to the setting in the "Invalid
Door" column.