EverFocus EFC304 User Manual page 59

Nav ip access controller
Hide thumbs Also See for EFC304:
Table of Contents

Advertisement

5.9.5.5
Door Act Setting On Fire
The controller allows the user to choose one of two behaviors to occur when a fire alarm is triggered:
fail-safe or fail-secure. Door fail-safe at fire alarm means the door will be kept unlocked when there is a
fire alarm input. Door fail-secure at fire alarm means the door will be locked when the fire alarm comes
in.
In submenu list of "Alarm Input Setting", press
the door behavior at fire alarm:
Press
to enter to the setting, LCD screen shows the current setting status of the door action when
firm alarm is triggered.
In the menu shown above, press numeric key 1~8 to toggle the door action between fail-safe and fail-
secure. (The numbers correspond to the number of door modules installed in the controller) "Y"
indicates fail-safe; "N" indicates fail-secure.
The default setting for door control at fire alarm is all the doors are fail-safe, i.e. all the doors will be
unlocked during a fire alarm.
5.9.5.6
Arm Delay Time Setting
When an arm operation is executed, all active arm zones will enter ARM enabled status only after a
certain time delay, which is called ARM delay time. When a card with ARM enabled is swiped to pass a
door, system will not generate an alarm within the arm delay period so that cardholder has time to
disarm the system.
The details to set ARM delay time is as following. And the alarm delay time can be set to different
durations. In submenu list of "Alarm Input Setting", press
submenu to set the arm delay time:
Press
to set ARM delay time at the following window:
System will display the current delay time as shown below. Use numeric keys to input the desired ARM
delay time. Enter minutes as a 3-digit number 0~999 and seconds as a 2-digit number 0~59. The default
value of ARM delay time is 30 seconds.
Press
to confirm. Press
and
Door Act Setting
on Fire
Door act onfire:
NNNNNNNN
Arm Delay Time
Setting
Arm Delay Time
000Min 30Sec
to exit without effecting any change.
51
NAV IP Access Controller
to navigate to the below submenu to set
and
to navigate to the below

Advertisement

Table of Contents
loading

This manual is also suitable for:

Efc302Efc308Efc306

Table of Contents