Press numeric keys to input the specified alarm time for the event. Press
to discard the change just made.
5.9.6.2
Event Alarm Action Setting
Press
at the below screen to configure event alarm action setting.
The event alarm action defines which alarm output can be triggered by the event. As we explained
before, NAV Controller can take main modules, up to 4 door modules and 1 alarm module, total 18
alarm output. Users will be able to configure the event to trigger any one or multiple outputs from those
18 alarm outputs.
The event alarm action setting includes three submenus, shown in below.
Event Alarm action
on Main Module
The alarm output setting on these three screens are the similar. For example, the fire alarm event
actions on door module will look like:
The top line indicates the event to be configured. The bottom line is the setting of alarm outputs on 4
door modules. Y indicates there is alarm output (relay energized) and N indicates there is no alarm
output (relay not energized). R refers specifically to alarm output on the door module, indicating that
alarm output will be generated only if the event occurs on the corresponding door. The above example
means the alarm output relay at door 1 will be energized if door forced open event happens on any door,
the alarm output relay at door 2 does not respond to any door forced open event, and same as door 4 to
8. Door 3 indicates the alarm output relay on door 3 will be energized if and only if the door 3 got a
forced open event.
Note "R" option for alarm output does not apply to alarm module and main module, since they don't
naturally correspond to a door control.
In the above menu, press numeric key 1~8 to toggle the alarm output actions of this event on the door
module among Y, N, and R (only for door module). Press
action settings.
The default setting of all the event alarm actions on main module, door module and alarm modules are
all disabled. The event alarm actions for main module and door modules are listed below. Default
settings for event alarm actions on alarm module are same as door module, not listed here.
SYS Password Fail
NN
ARM Password Fail
NN
Panic Open
000Min 10Sec
EventAlarm action
Setting
Event Alarm action
on Door Module
Door Forced Open
YNRNNNN
Main module
Event Alarm action
on Alarm Module
and
Door module
SYS Password Fail
NNNNNNN
ARM Password Fail
NNNNNNN
56
NAV IP Access Controller
to confirm and press
to navigate to other alarm